DFC10 SERIES
SINGLE OUTPUT
DESCRIPTION
FEATURES
The DFC10 Series provides power converter solutions to meet
commercial and industrial requirements. With power densities
above 11 watts per cubic inch (0.67 watts per cm3), overcurrent
protection, and five-sided shielded case, the DFC10 meets the
most rigorous needs in an industry standard case size. The
220KHz operating frequency of the DFC10 Series allows an
increased power density while including adequate heat sinking
and input/output filtering. This eliminates the need for external
components in most applications. Full overload protection is
provided by pulse-by-pulse current limiting.
• High Power Density, up to
11 Watts per Cubic Inch (0.67 watts per cm3)
• Efficiencies to 83% (Lower for 3.3V)
• Low Input to Output Capacitance
• 700V Isolation(1544V for 48V Converters)
• Continuous Overcurrent Protection
• 3.3Volt Output Available
• Five-Side Shielded Copper Case
• Extended Input Range (2:1)
BOTTOM VIEW
2.02
(51.31)
SIDE VIEW
0.040 (1.02)
DIA TYP
Selection Chart
Input Range
VDC (4)
0.300
3
(7.62)
Output
VDC
Output
mA
Model
0.000
1
Min
Max
1.02
0.100
(2.54)
0.200
(5.08)
4
5
(25.91)
2
9
9
9
9
18
18
18
18
36
36
36
36
18
18
18
18
36
36
36
36
72
72
72
72
3.33
5
12
15
3.33
5
12
15
3.33
5
12
15
2000
2000
900
DFC10E12S3.3
DFC10E12S5
DFC10E12S12
DFC10E12S15
DFC10E24S3.3
DFC10E24S5
DFC10E24S12
DFC10E24S15
DFC10E48S3.3
DFC10E48S5
DFC10E48S12
DFC10E48S15
0.500
(12.70)
0.61
(15.5)
700
2000
2000
900
700
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.020 inches
X.XXX dimensions: ±0.005 inches
2000
2000
900
700
Pin
1
Function
+INPUT
-INPUT
+OUT
General Specifications (1)
All Models
Units
2
Isolation (2)
3
Isolation Voltage
Input to Output 12V, 24V
Input to Output 48V
10 µA Leakage
Input to Output
Capacitance
4
NO PIN
-OUT
MIN
MIN
700
1544
VDC
pF
5
NOTES
TYP
400
(1) All parameters measured at Tc = 25°C, nominal input voltage and full rated load unless otherwise noted.
Refer to the DC/DC Technical Reference Section for the definition of terms, measurement circuits and
other information.
Enviromental
Case Operating Range, Tc
No Derating
-40
90
-50
100
-55
105
MIN
MAX
° C
° C
(2) The Case is tied to the -Input pin.
(3) The functional temperature range is intended to give an additional data point for use in evaluating this
power supply. At the low functional temperature the power supply will function with no side effects,
however, sustained operation at the high functional temperature will reduce expected operational life.
The data sheet specifications are not guaranteed beyond the case operating range.
(4) The case thermal impedance is specified as the case temperature rise over ambient per package watt
dissipated.
MIN
MAX
Case Functional Range (3)
Storage Range
MIN
MAX
° C
Thermal Impedance (4)
General
TYP
15
° C/Watt
MTBF (Calculated)
Unit Weight
TYP
TYP
800,000
1.0/28
HRS
oz/gm
Chassis Mounting Kit 12V, 24V
Chassis Mounting Kit 48V
CM2B2
CM2A1
14