APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
STORAGE
-35 C TO +105C (NOTE1)
-10 C TO +60C (NOTE3)
TEMPERATURE RANGE
OPERATING
RATING
20% TO 80% (NOTE2)
DF62B-24EP-2.2C(##)
40% TO 70% (NOTE3)
HUMIDITY RANGE
APPLICABLE
HUMIDITY RANGE
VOLTAGE
AC/DC
250V
CONNECTOR
VOLTAGE
CURRENT
UL・
C-UL
RATING
AWG 22 : 2.5A
AWG 24 : 2A
AWG 26-30 : 1A
250
V
AC/DC
2
CURRENT
:
:
AWG 22
AWG 24
AWG 26-30
3A
2A
1A
APPLICABLE
CONTACT
:
DF62-22SC*
DF62-2428SC*
DF62-30SC*
OPERATING
TEMPERATURE
RANGE
-35 C TO +75C (NOTE1)
SPECIFICATIONS
ITEM
TEST METHOD
GENERAL EXAMINATION VISUALLY AND BY MEASURING INSTRUMENT.
MARKING CONFIRMED VISUALLY.
REQUIREMENTS
QT AT
CONSTRUCTION
ACCORDING TO DRAWING.
X
X
X
X
ELECTRIC CHARACTERISTICS
INSULATION RESISTANCE
500 V DC.
1000 M MIN.
-
-
X
X
650 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
VOLTAGE PROOF
MECHANICAL CHARACTERISTICS
30 TIMES INSERTION AND EXTRACTION.
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
MECHANICAL
OPERATION
VIBRATION
-
-
-
X
X
X
FREQUENCY 10 TO 55 Hz, SINGLE AMPLITUDE
0.75 mm, AT 10 CYCLES FOR 3 DIRECTION.
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES EACH NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
SHOCK
FOR 3 BOTH AXIAL DIRECTIONS.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ± 2℃ , 90 TO 95 %, 96 h.
①INSULATION RESISTANCE: 1000 M MIN.
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
-
-
X
X
(STEADY STATE)
(AFTER LEAVING THE ROOM TEMPERATURE FOR
1-2h.)
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55℃→ +85℃
①INSULATION RESISTANCE: 1000 M MIN.
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
TIME
30min→ 30min
UNDER 5 CYCLES.
(THE TRANSFERRING TIME OF THE TANK IS 2-3 min)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
REMARKS
NOTE 1: INCLUDE THE TEMPERATURE RISING BY CURRENT.
NOTE 2:NO CONDENSING
NOTE 3:APPLY TO THE CONDITION OF LONG TERM STORAGE FOR UNUSED PRODUCTS BEFORE PCB ON BOARD, AFTER PCB BOARD ,
OPERATING TEMPERATURE AND HUMIDITY RANGE IS APPLIED FOR INTERIM STORAGE DURING TRANSPORTATION.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
2
△
1
DIS-H-00019309
RI.GENDA
SZ.ONO
20231023
20130917
20130913
20130913
20130909
REMARKS
APPROVED
CHECKED
DESIGNED
DRAWN
KI.AKIYAMA
OM.MIYAMOTO
TH.YOSHIZAWA
MI.SAKIMURA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-348676-11-01
DF62C-24S-2.2C(11)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
2
△
1/1
CL0544-0541-6-11
FORM HD0011-2-1