APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
STORAGE
-35 C TO +105C (NOTE1)
20% TO 80% (NOTE2)
DF62B-6EP-2.2C(##)
-10 C TO +60C (NOTE3)
TEMPERATURE RANGE
OPERATING
RATING
40% TO 70% (NOTE3)
HUMIDITY RANGE
APPLICABLE
HUMIDITY RANGE
VOLTAGE
AC/DC
250V
CONNECTOR
VOLTAGE
CURRENT
CURRENT
UL・
C-UL
RATING
250
V
AC/DC
AWG 22 : 3A/pin
AWG 24 : 2A/pin
AWG 26-30 : 1A/pin
:
:
AWG 22
AWG 24
AWG 26-30 :1A/pin
3A/pin
2A/pin
1
OPERATING
TEMPERATURE
RANGE
APPLICABLE
CONTACT
DF62-22SC*
DF62-2428SC*
DF62-30SC*
-35 C TO +75C (NOTE1)
SPECIFICATIONS
ITEM
TEST METHOD
GENERAL EXAMINATION VISUALLY AND BY MEASURING INSTRUMENT.
MARKING CONFIRMED VISUALLY.
REQUIREMENTS
QT AT
CONSTRUCTION
ACCORDING TO DRAWING.
X
X
X
X
ELECTRIC CHARACTERISTICS
INSULATION RESISTANCE
500 V DC.
1000 M MIN.
-
-
X
X
650 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
VOLTAGE PROOF
MECHANICAL CHARACTERISTICS
30 TIMES INSERTION AND EXTRACTION.
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
MECHANICAL
OPERATION
VIBRATION
-
-
-
X
X
X
FREQUENCY 10 TO 55 Hz, SINGLE AMPLITUDE
0.75 mm, AT 10 CYCLES FOR 3 DIRECTION.
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES EACH NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
SHOCK
FOR 3 BOTH AXIAL DIRECTIONS.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ± 2℃ , 90 TO 95 %, 96 h.
①INSULATION RESISTANCE: 1000 M MIN.
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
-
-
X
X
(STEADY STATE)
(AFTER LEAVING THE ROOM TEMPERATURE FOR
1~2h.)
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55℃→ +85℃
①INSULATION RESISTANCE: 1000 M MIN.
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
TIME
30min→ 30min
UNDER 5 CYCLES.
(THE TRANSFERRING TIME OF THE TANK IS 2~3 min)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1~2h.)
NOTE 1: INCLUDE THE TEMPERATURE RISING BY CURRENT.
NOTE2:NO CONDENSING
NOTE3:APPLY TO THE CONDITION OF LONG TERM STORAGE FOR UNUSED PRODUCTS BEFOR PCB ON BOARD, AFTER PCB ON BOARD,
OPERATING TEMPERATURE AND HUMIDITTY RANGE IS APPLIED FOR INTERIM STRAGE DURING TRANSPORTATION.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
1
△
1
DIS-H-00019419
RI.GENDA
SZ.ONO
20231115
20130524
20130524
20130523
20130523
REMARKS
APPROVED
CHECKED
DESIGNED
DRAWN
KI.AKIYAMA
HK.UMEHARA
TS.KUMAZAWA
TS.KUMAZAWA
Unless otherwise specified, refer to JIS C 5402.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-351974-00-00
DF62C-6S-2.2C
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1
△
1/1
CL0544-0569-5-00
FORM HD0011-2-1