DE (ADE)
VDE
COMPACT
HIGH-INSULATION
POLARIZED POWER RELAY
DE RELAYS (ADE)
FEATURES
12.5
.492
25.0
.984
• Conforms to European safety
standards (VDE0700 and VDE0631)
Insulating distance between coil and
contacts:
• Low operating power
Nominal operating power at 200 mW
(Single side stable, 2 coil latching)
12.5
.492
• Compact body saves space
Size: 12.5(W) 25.0(L) 12.5(H) mm
.492(W) .984(L) .492(H) inch
Clearance Min. 8mm .315 inch
Creepage distance Min. 8mm .315 inch
• Extensive product line-up
mm inch
• UL/CSA, VDE approved
• Surge voltage between contact and
coil 12 kV
SPECIFICATIONS
Contact
Characteristics
1 Form A
1 Form B
Max. operating speed
20 cpm (at rated load)
Arrangement
1 Form A
2 Form A
Min. 1,000 M
(at 500 V DC)
Initial insulation resistance*1
Contact material
AgSnO2 type
Initial contact resis-
tance, max. (By voltage
drop 6V DC 1A)
Between open contacts
1,000 Vrms
Initial
30m
4,000 Vrms (2 Form A,
1 Form A 1 Form B)
breakdown Between contact sets
voltage*2
Nominal
switching
capacity
Between contact and coil
Surge voltage between contact and coil*3
5,000 Vrms
10A 250V AC, 8A 250V AC, 8A 250V AC,
10A 30V DC 8A 30V DC
8A 30V DC
Min. 12,000 V (initial)
Max. 10ms (typ. 5ms)
[Max. 10ms (typ. 4ms)]
(at 20C 68F)
Max.
switching
power
Operate time [Set time]*4
2,500 VA*,
300W
2,000 VA*,
240W
2,000 VA*,
240W
Max. 5ms (typ. 2ms)
[Max. 10ms (typ. 4ms)]
(at 20C 68F)
Rating
(resistive
load)
Max.
switching
voltage
Release time (without diode) [Reset time]*4
440V AC,
230V DC
440V AC,
230V DC
440V AC,
230V DC
Temperature rise (at 70C)*5
Max. 50C
Min. 196 m/s2{20 G}
Min. 980 m/s2{100 G}
Max.
switching
current
10A (16A)*
8A (16A)*
8A (16A)*
Functional*6
Destructive*7
Shock resistance
Min. switch-
ing capac-
ity#1
10 to 55 Hz at double
amplitude of 2 mm
Functional*8
Vibration resistance
100 mA, 5 V DC
107
10 to 55 Hz at double
amplitude of 3 mm
Destructive
Mechanical
(at 300cpm)
Conditions for operation,
Ambient temp.
–40C to 70C
–40F to 158F
Electrical
(at 20 cpm)
(resistive load)
transport and storage*9
Expected
life (min.
105(AC)
5 104(DC)
105
(Not freezing and condens-
ing at low temperature)
Humidity
5 to 85% R.H.
operations)
Electrical
Unit weight
Approx. 7 g .25 oz
(16A / 230 V
25000
20000
AC resistive)*
Coil (at 20C, 68F)
Remarks
Nominal operating power
200 mW
*
*
*
*
*
*
*
*
*
16A possible for one contact set only with max. 4000 VA switching power.
Measurement at same location as “Initial breakdown voltage” section.
Detection current: 10mA
Wave is standard shock voltage of 1.2 50s according to JEC-212-1981
Nominal operating voltage applied to the coil, excluding contact bounce time.
By resistive method
Half-wave pulse of sine wave: 11ms, detection time: 10ms.
Half-wave pulse of sine wave: 6ms
Detection time: 10ms
*9 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT
ENVIRONMENT section in Relay Technical Information.
Single side stable
1 coil latching
2 coil latching
1
2
3
4
5
6
7
8
100 mW
200 mW
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
ds_61A01_en_de: 100811D
1