PMIC with Integrated Charger and
Smart Power Selector for Handheld Devices
MA8671X
ELECTRICAL CHARACTERISTICS (continued)
(DC, USB, BVSET, UOK, DOK, LX_ unconnected; V
= V /2, V
= V
= 0V, V
= 4V, CEN = low, USUS = low, EN = high,
BAT
THM
L
PG_
AGND
V
R
= V
= 3.3V, V
VL
= 0V, C
CT
= 1µF, C
BP
= 1µF, C
= 10µF, PV1 = PV2 = PV3 = PV4 = PV5 = SYS, R
= 3kΩ,
PEN1
CISET
PEN2
PWM
OUT4
OUT5
SYS
DISET
= 3kΩ, C = 0.1µF, C = 0.15µF, C = 0.01µF, V
= 1.1V, V
= 1.1V, V
= 1.1V, T = -40°C to +85°C, unless other-
FB3 A
FB1
FB2
wise noted.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
Low-power USB charging from the USB
MIN
TYP
MAX
UNITS
87
92
100
input, DC unconnected, R
PEN2 = low, USUS = low
= 3kΩ,
CISET
Low-power USB charging from the DC
input, R = 3kΩ, PEN1 = low,
PEN2 = low, USUS = low
87
92
100
500
500
230
425
850
CISET
High-power USB charging from the USB
input, DC unconnected, R
PEN2 = high, USUS = low
= 3kΩ,
450
450
170
375
750
472
472
200
400
802
CISET
High-power USB charging from the DC
input, R = 3kΩ, PEN2 = high,
BAT Fast-Charge Current Limit
mA
CISET
USUS = low
AC-to-DC adapter charging from the DC
input, R = 3kΩ, R = 15kΩ,
DISET
CISET
PEN1 = high
AC-to-DC adapter charging from the DC
input, R = 3kΩ, R = 7.5kΩ,
DISET
CISET
PEN1 = high
AC-to-DC adapter charging from the DC
input, R = 3kΩ, R = 3.74kΩ,
DISET
CISET
PEN1 = high
BAT Prequalification Current
Top-Off Threshold
V
= 2.5V, R
= 3.74kΩ
65
20
82
30
100
40
mA
mA
BAT
CISET
CISET
T
A
= +25°C, R
= 3.74kΩ (Note 6)
No DC or USB power
connected
0
1
+5
+5
EN = low,
= +25°C
BAT Leakage Current
Charger Soft-Start Time
µA
T
A
DC and/or USB power
connected, CEN = high
-5
Slew rate
450
1.10
0.22
0.88
mA/ms
ms
Time from 0mA to 500mA
Time from 0mA to 100mA
Time from 100mA to 500mA
t
SS_CHG
Timer Accuracy
C
= 0.15µF
-20
+20
350
%
CT
CISET voltage when the fast-charge timer
suspends; 300mV translates to 20% of the
maximum fast-charge current limit
Timer Suspend Threshold
250
300
750
mV
CISET voltage when the fast-charge timer
suspends; 750mV translates to 50% of the
maximum fast-charge current limit
Timer Extend Threshold
700
800
mV
_______________________________________________________________________________________
7