DCM™ in a VIA Package
DC-DC Converter
DCM3714xD2J13D0yzz
S
®
C
US
C
NRTL US
Isolated, Regulated DC Converter
Features & Benefits
Product Ratings
VIN = 180 V to 420 V
POUT = 400 W
• Isolated, regulated DC-to-DC converter
• Up to 400 W, 33.33 A continuous
VOUT = 12.0 V
(7.2 V to 13.2 V Trim)
IOUT = 33.33 A
• 93.5% peak efficiency
• 206 W/in3 Power density
Product Description
• Wide input range 180 – 420 Vdc
The DCM in a VIA package is an Isolated, Regulated DC-to-DC
Converter, operating from an unregulated, wide range input to
generate an isolated 12.0 Vdc output. With its high frequency
zero voltage switching (ZVS) topology, the DCM converter
consistently delivers high efficiency across the input line range.
The DCM provides tight output voltage regulation and offers a
secondary-referenced control interface for trim, enable, and
remote sense operation. DCM converters and downstream
DC-DC products support efficient power distribution, providing
superior power system performance and connectivity from a
variety of unregulated power sources to the point-of-load.
• Safety Extra Low Voltage (SELV) 12.0 V Nominal Output
• ZVS high frequency switching
• Allows remote sense or local sense operation
• Tight regulation over all line and load conditions
• Fully operational current limit
• OV, OC, UV, short circuit and thermal protection
• Available in chassis mount and through hole VIA package
n 3.750” x 1.400” x 0.370”
The VIA package offers flexible thermal management options
with very low top and bottom side thermal impedances.
(95.13 mm x 35.5 mm x 9.40 mm)
Typical Applications
• Industrial
• Process Control
• Heavy Equipment
• Defense / Aeorspace
Size:
3.750 x 1.400 x 0.370 in
95.13 x 35.5 x 9.40 mm
Part Ordering Information
Max
Input
Voltage
Max
Output Output
Voltage Power
Max
Product
Function
Package
Length
Package
Width
Package
Type
Range
Ratio
Product Grade
(Case Temperature)
Option Field
DCM
37
14
x
D2
J
13
D0
y
z
z
DCM =
DC-DC
Converter
C = -20 to 100°C[1]
T = -40 to 100°C[1]
01 = Chassis/Analog
05 = Short Pin/Analog
Length in
Width in
B = Board VIA
Internal Reference
Inches x 10 Inches x 10 V = Chassis VIA
M = -55 to 100°C[1][2] 09 = Long Pin/Analog
[1] High Temperature Power Derating may apply, see Thermal Specified Operating Area, Figure 1 on Page 4.
[2] M-Grade available on selected models. Consult vicorpower.com for details.