SIL 2 Repeater Power Supply
Hart compatible DIN-Rail
Models D1014S, D1014D
D1014
Characteristics:
Technical Data:
Supply:
General Description:
12-24 Vdc nom (10 to 30 Vdc) reverse polarity protected,
ripple within voltage limits ≤ 5 Vpp.
The single and dual channel DIN Rail Repeater Power Supply, D1014S and D1014D
is a high integrity analog input interface suitable for applications requiring SIL 2 level
(according to IEC61508:2010) in safety related system for high risk industries.
Provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA
transmitters located in Hazardous Area, and repeats the current in floating circuit
to drive a Safe Area load.
The circuit allows bi-directional communication signals, for Hart transmitters.
Function:
1 or 2 totally independent and isolated channels I.S. analog input for 2 wires loop
powered Hart transmitters, provides 3 port isolation (input/output/supply) and
current (source or sink) or voltage output signal.
Signalling LED:
Power supply indication (green).
Field Configurability:
mA (source or sink) or V output signal.
Hart Communication Frequency Band:
0.5 to 2.5 KHz within 3 dB.
EMC:
Fully compliant with CE marking applicable requirements.
Current consumption @ 24 V: 110 mA for 2 channels D1014D,
55 mA for 1 channel D1014S with 20 mA output typical.
Current consumption @ 12 V: 220 mA for 2 channels D1014D,
110 mA for 1 channel D1014S with 20 mA output typical.
Power dissipation: 1.8 W for 2 channels D1014D, 0.9 W for 1 channel D1014S
with 24 V supply voltage and 20 mA output typical.
Max. power consumption: at 30 V supply voltage and short circuit condition,
3.4 W for 2 channels D1014D, 1.7 W for 1 channel D1014S.
Isolation (Test Voltage):
I.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; I.S. In/I.S. In 500 V;
Out/Supply 500 V; Out/Out 500 V.
Input:
4 to 20 mA (2 wire Tx current limited at ≈ 25 mA).
Transmitter line voltage:
≥ 15.0 V at 20 mA with max. 20 mVrms ripple on 0.5 to 2.5 KHz frequency band.
Output:
4 to 20 mA, on max. 600 Ω load in source mode;
V min. 5 V at 0 Ω load V max. 30 V in sink mode, current limited at ≈ 25 mA or
1 to 5 V on internal 250 Ω shunt (or 2 to 10 V on internal 500 Ω shunt on request).
Response time: 20 ms (10 to 90 % step change).
Output ripple: ≤ 20 mVrms on 250 Ω communication load on 0.5 to 2.5 KHz band.
Frequency response: 0.5 to 2.5 KHz bidirectional within 3 dB (Hart protocol).
Performance:
Functional Safety Management Certification:
G.M. International is certified by TUV to conform to IEC61508:2010
part 1 clauses 5-6 for safety related systems up to and included SIL3.
FSM
SIL 3
Ref. Conditions 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature.
Calibration accuracy: ≤ ± 0.1 % of full scale.
Linearity error: ≤ ± 0.1 % of full scale.
Supply voltage influence: ≤ ± 0.05 % of full scale for a min to max supply change.
Load influence: ≤ ± 0.05 % of full scale for a 0 to 100 % load resistance change.
Temperature influence: ≤ ± 0.01 % on zero and span for a 1 °C change.
Compatibility:
CE mark compliant, conforms to Directive:
2014/34/EU ATEX, 2014/30/EU EMC, 2014/35/EU LVD, 2011/65/EU RoHS.
Environmental conditions:
Operating: temperature limits -20 to + 60 °C, relative humidity max 95 %.
Storage: temperature limits – 45 to + 80 °C.
Safety Description:
Front Panel and Features:
1
5
2
6
3
7
4
8
• SIL 2 according to IEC 61508:2010 Ed. 2 for
Tproof = 9 / 10 years (≤10% / >10 % of total SIF).
• PFDavg (1 year) 1.05 E-04, SFF 87.01%.
ATEX: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; II 3G Ex nA IIC T4 Gc
IECEx / INMETRO: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I; Ex nA IIC T4 Gc
UL: AIS / I, II, III / 1 / ABCDEFG, [AEx ia] IIC
• SIL 3 Systematic capability.
• 2 fully independent channels.
C-UL: AIS / I, II, III / 1 / ABCDEFG, [Ex ia] IIC
• Input from Zone 0 (Zone 20), Division 1,
FM: NI / I / 2 / ABCD / T4, NI / I / 2 / IIC / T4, AIS / I, II, III / 1 / ABCDEFG, AEx [ia] IIC
FM-C: NI / I / 2 / ABCD / T4, NI / I / 2 / IIC / T4, AIS / I, II, III / 1 / ABCDEFG, Ex [ia] IIC
EAC-EX: 2Ex nA [ia Ga] IIC T4 Gc X, [Ex ia Da] IIIC X, [Ex ia Ma] I X
UKR TR n. 898: 2ExnAiaIICT4 X, ExiaI X
associated apparatus and non-sparking electrical equipment.
Uo/Voc = 25.2 V, Io/Isc = 93 mA, Po/Po = 585 mW at terminals 14-15, 10-11.
Um = 250 Vrms, -20 °C ≤ Ta ≤ 60 °C.
installation in Zone 2, Division 2.
• 4-20 mA Input, Output Signal.
• Hart compatible.
• Input and Output short circuit proof.
• High Accuracy.
Approvals:
• Three port isolation, Input/Output/Supply.
DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN60079-26.
IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, IEC60079-26.
IMQ 09 ATEX 013 X conforms to EN60079-0, EN60079-15.
IECEx IMQ 13.0011X conforms to IEC60079-0, IEC60079-15.
INMETRO DNV 13.0108 X conforms to ABNT NBR IEC60079-0, ABNT NBR IEC60079-
11, ABNT NBR IEC60079-15, ABNT NBR IEC60079-26, ABNT NBR IEC 61241-11.
UL & C-UL E222308 conforms to UL913, UL 60079-0, UL60079-11, UL60079-15
ANSI/ISA 12.12.01 for UL and CSA-C22.2 No.157-92, CSA-E60079-0, CSA-E60079-11,
CSA-C22.2 No. 213 and CSA-E60079-15 for C-UL.
1
2
• EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1
• In-field programmability by DIP Switch.
PWR ON
• ATEX, IECEx, UL & C-UL, FM & FM-C, INMETRO, EAC-EX,
• TUÜKVRFTuRnnct.io8n9a8l,STaÜfVetyCCeretirftiicfiactaiotinosn..
• Type Approval Certificate DNV and KR for
D1014
maritime applications.
FM & FM-C No. 3024643, 3029921C, conforms to Class 3600, 3610, 3611, 3810,
ANSI/ISA 12.12.02, ANSI/ISA 60079-0, ANSI/ISA 60079-11, C22.2 No.142,
C22.2 No.157, C22.2 No.213, E60079-0, E60079-11, E60079-15,
GOST R 12.2.007.0-75, R 51330.0-99, R 51330.10-99
• High Reliability, SMD components.
• High Density, two channels per unit.
9
10 11 12
• Simplified installation using standard
GOST 12.2.007.0,22782.0,22782.5
DIN Rail and plug-in terminal blocks.
TÜV Certificate No. C-IS-236198-03, SIL 2 conforms to IEC61508:2010 Ed.2.
TÜV Certificate No. C-IS-236198-09, SIL 3 Functional Safety Certificate conforms to
IEC61508:2010 Ed.2, for Management of Functional Safety.
DNV No.A-13625 and KR No.MIL20769-EL001 Certificates for maritime applications .
Mounting:
13 14 15 16
• 250 Vrms (Um) max. voltage allowed to the
instruments associated with the barrier.
Ordering Information:
T35 DIN Rail according to EN50022.
Weight: about 170 g D1014D, 115 g D1014S.
Model:
D1014
Connection: by polarized plug-in disconnect screw terminal blocks to accomodate
terminations up to 2.5 mm2.
1 channel
2 channels
S
D
Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4,
Class I, Division 2, Groups A, B, C, D Temperature Code T4 and
Class I, Zone 2, Group IIC, IIB, IIA T4 installation.
Protection class: IP 20.
Dimensions: Width 22.5 mm, Depth 99 mm, Height 114.5 mm.
Power Bus enclosure
Power Bus and DIN-Rail accessories:
DIN rail anchor MCHP065
/B
DIN rail stopper MOR016
Terminal block male MOR017
Terminal block female MOR022
G.M. International DTS0181-16 Page 1/2
www.gmintsrl.com