CY7C4421V/4201V/4211V/4221V
CY7C4231V/4241V/4251V
DC Input Voltage ............................................–0.5V to +5.0V
Output Current into Outputs (LOW)............................. 20 mA
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Static Discharge Voltage...........................................> 2001V
(per MIL-STD-883, Method 3015)
Storage Temperature ...................................–65°C to +150°C
Latch-up Current.....................................................> 200 mA
Ambient Temperature with
Power Applied............................................. –-55°C to +125°C
Operating Range
Supply Voltage to Ground Potential............... –0.5V to +5.0V
Range
Ambient Temperature
VCC
DC Voltage Applied to Outputs
in High-Z State ............................................... –0.5V to +5.0V
Commercial
0°C to +70°C
3.3V ± 300 mV
Electrical Characteristics Over the Operating Range
7C42X1V-15
7C42X1V-25
7C42X1V-35
Parameter
Description
Test Conditions
VCC = Min.,
Min.
Max.
Min.
Max.
Min.
Max.
Unit
VOH
Output HIGH Voltage
2.4
2.4
2.4
V
IOH = −2.0 mA
VOL
Output LOW Voltage
VCC = Min.,
IOL = 8.0 mA
0.4
0.4
0.4
V
VIH
VIL
IIX
Input HIGH Voltage
Input LOW Voltage
2.0
−0.5
−10
−10
5.0
0.8
2.0
−0.5
−10
−10
5.0
0.8
2.0
−0.5
−10
−10
5.0
0.8
V
V
Input Leakage Current VCC = Max.
+10
+10
+10
+10
+10
+10
µA
µA
IOZL
IOZH
Output OFF, High Z
Current
OE > VIH,
SS < VO < VCC
V
[4]
ICC
Active Power Supply
Current
Com’l
20
6
20
6
20
6
mA
mA
[5]
ISB
Average Standby
Current
Com’l
Capacitance[6]
Parameter
Description
Input Capacitance
Output Capacitance
Test Conditions
TA = 25°C, f = 1 MHz,
VCC = 5.0V
Max.
Unit
CIN
5
7
pF
pF
COUT
AC Test Loads and Waveforms[7, 8]
R1= 330 Ω
3.3V
ALL INPUT PULSES
OUTPUT
3.0V
GND
90%
10%
90%
10%
R2=510 Ω
C
L
≤ 3 ns
≤ 3 ns
INCLUDING
JIG AND
SCOPE
Equivalent to:
THÉVENIN EQUIVALENT
Rth=200 Ω
OUTPUT
Vth=2.0V
Notes:
4. Outputs open. Tested at Frequency = 20 MHz.
5. All inputs = VCC – 0.2V, except WCLK and RCLK, which are switching at 20 MHz.
6. Tested initially and after any design or process changes that may affect these parameters.
7. CL = 30 pF for all AC parameters except for tOHZ
8. CL = 5 pF for tOHZ
.
.
Document #: 38-06010 Rev. *A
Page 7 of 17