CY62127DV20
MoBL2®
ADVANCE
INFORMATION
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
DC Input Voltage[3] ................................ −0.2V to VCC + 0.2V
Output Current into Outputs (LOW)............................. 20 mA
Storage Temperature .................................–65°C to +150°C
Static Discharge Voltage.......................................... > 2001V
(per MIL-STD-883, Method 3015)
Ambient Temperature with
Power Applied.............................................–55°C to +125°C
Latch-up Current .................................................... > 200 mA
Operating Range
Supply Voltage to Ground Potential
.........................................................−0.2V to VCCMAX + 0.2V
DC Voltage Applied to Outputs
in High-Z State[3]....................................−0.2V to VCC + 0.2V
Ambient
Range
Temperature (TA)
VCC
Industrial
−40°C to +85oC 1.65V to 2.2V
Product Portfolio
Power Dissipation
Operating, Icc (mA)
f = 1 MHz f = fMAX
V
CC Range(V)
Standby, ISB2 (µA)
Speed
(ns)
Product
Min.
Typ.[4]
Max.
Typ.[4]
Max.
Typ.[4]
Max.
7.5
Typ.[4]
Max.
4
CY62127DV20L
CY62127DV20LL
1.65
1.8
2.2
55
55
0.5
1
3.75
3.75
0.5
7.5
0.5
2.5
Notes:
3. VIL(min.) = −2.0V for pulse durations less than 20 ns.
4. Typical values are included for reference only and are not guaranteed or tested. Typical values are measured at VCC = VCC(typ), TA = 25°C.
Document #: 38-05301 Rev. **
Page 3 of 12