CR60 SERIES
60 Watt DC/DC Power Converters
Rev A
Wall Industries, Inc.
FEATURES
Input Under Voltage Protection
60 Watts Maximum Output Power
High Efficiency up to 92%
1600VDC I/O Isolation
Remote ON/OFF Control
Short Circuit, Over Voltage, Over Load, & Over Temp. Protection
Wide Operating Temperature Range: -40°C to +85°C
CE Mark Meets 2006/95/EC, 2011/95/EC, & 2004/108/EC
Compliant to RoHS EU Directive 2011/65/EU
UL60950-1, EN60950-1, & IEC60950-1 Safety Approvals
Optional Heatsink Available (Suffix “HS”)
2:1 Wide Input Voltage Ranges
Six-Sided Continuous Shielding
Low Stand-by Power Consumption
No Minimum Load Required
Single and Dual Outputs
Size:
2.00 x 1.00 x 0.40 inches
(50.8 x 25.4 x 10.2 mm)
DESCRIPTION
The CR60 series of DC/DC power converters provides 60 Watts of output power in an industry standard 2.00” x 1.00”
x 0.40” package and footprint. This series has single and dual output models with 2:1 wide input voltage ranges of 9-
18VDC, 18-36VDC, and 36-75VDC. Some features include high efficiency up to 92%, 1600VDC I/O isolation, six-sided
shielding, and remote ON/OFF control. These converters are also protected against short circuit, over voltage, over
load, and over temperature conditions. All models are RoHS compliant and have UL60950-1, EN60950-1, and
IEC60950-1 safety approvals. This series is best suited for use in wireless networks, telecom/datacom, industry
control systems, semiconductor equipment, and distributed power architectures.
Applications:
Wireless Networks
Telecom/Datacom
Industry Control Systems
Distributed Power Architectures
Semiconductor Equipment
MODEL SELECTION TABLE
SINGLE OUTPUT MODELS
Output
Voltage
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
Output Current
Min Load
Output
No Load
Output
Power
39.6W
60W
60W
60W
60W
39.6W
60W
60W
60W
60W
39.6W
60W
60W
60W
Maximum
Capacitive Load
32000μF
30000μF
5850μF
Model Number Input Voltage Range
CR12S33-60
Efficiency
Ripple & Noise Input Current
Max Load
12A
12A
5A
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
75mVp-p
75mVp-p
100mVp-p
100mVp-p
150mVp-p
75mVp-p
75mVp-p
100mVp-p
100mVp-p
150mVp-p
75mVp-p
75mVp-p
100mVp-p
100mVp-p
150mVp-p
10mA
10mA
10mA
10mA
10mA
10mA
10mA
10mA
10mA
10mA
10mA
10mA
10mA
10mA
10mA
89%
90.5%
90.5%
91.5%
91.5%
89%
92%
92%
92%
92%
CR12S05-60
CR12S12-60
CR12S15-60
12 VDC
(9 - 18 VDC)
4A
3900μF
2000μF
32000μF
30000μF
5850μF
3900μF
2000μF
32000μF
30000μF
5850μF
CR12S24-60
CR24S33-60
2.5A
12A
12A
5A
CR24S05-60
CR24S12-60
CR24S15-60
24 VDC
(18 - 36 VDC)
4A
CR24S24-60
CR48S33-60
2.5A
12A
12A
5A
4A
2.5A
89%
92%
92%
92%
CR48S05-60
CR48S12-60
CR48S15-60
48 VDC
(36 - 75 VDC)
3900μF
2000μF
CR48S24-60
60W
92%
DUAL OUTPUT MODELS
Output
Voltage
12 VDC
15 VDC
24 VDC
12 VDC
15 VDC
24 VDC
12 VDC
15 VDC
24 VDC
Output Current
Output
No Load
Output
Power
60W
60W
60W
60W
60W
60W
60W
60W
60W
Maximum
Capacitive Load
3900μF
Model Number Input Voltage Range
Efficiency
Ripple & Noise Input Current
Min Load
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
Max Load
2.5A
2A
CR12D12-60
12 VDC
100mVp-p
100mVp-p
150mVp-p
100mVp-p
100mVp-p
150mVp-p
100mVp-p
100mVp-p
150mVp-p
10mA
10mA
10mA
10mA
10mA
10mA
10mA
10mA
10mA
90%
90%
90%
90%
90%
90%
91%
91%
91%
CR12D15-60
CR12D24-60
2400μF
1000μF
3900μF
2400μF
1000μF
3900μF
2400μF
1000μF
(9 - 18 VDC)
1.25A
2.5A
2A
CR24D12-60
24 VDC
CR24D15-60
CR24D24-60
(18 - 36 VDC)
1.25A
2.5A
2A
CR48D12-60
48 VDC
CR48D15-60
(36 - 75 VDC)
CR48D24-60
1.25A
NOTES
1. The CR60 series can only meet EMI Class A or Class B with external components added. Please contact factory for more information.
2. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. For 12VDC & 24VDC nominal input models we recommend
connecting an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220μF/100V) and a TVS (SMDJ58A, 58V, 3000 Watt peak pulse power) diode in parallel.
For 48VDC nominal input models we recommend connecting an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220μF/100V) and a TVS (SMDJ120A,
120V, 3000 Watt peak pulse power) diode connected in parallel.
3. Both positive logic and negative logic remote ON/OFF control is available. Positive logic remote ON/OFF comes standard; for negative logic remote ON/OFF add the
suffix “R” to the model number (Ex: CR48S12-60R).
4. Optional heatsink is available. Please call factory for ordering details.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
Wall Industries, Inc. • 5 Watson Brook Road, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
03/27/2013
Page 1 of 5
website: www.wallindustries.com • e-mail: sales@wallindustries.com