C o m p o n e n t P o w e r D C - D C M o d u le s
5 0 - 7 0 0 Wa tts
TH E XP ERTS IN P O W ER
C P M S e rie s
Lo w P ro file
•
•
In d u s try S ta n d a rd Fo o tp rin t
•
W id e O p e ra tin g Te m p e ra tu re
•
Pa ra lle l O p e ra tio n
•
Re m o te O N/O FF
•
Ad ju s ta b le O u tp u t
•
O ve rvo lta g e & O ve rlo a d P ro te c tio n
S p e c ific a tio n
In p u t
G e n e ra l
Efficiency
Isolation
Input Voltage
•
18-36 VDC
36-76 VDC
45-160 VDC
88-370 VDC
200-400 VDC
(see tables)
•
•
Up to 89% dependant on model
3 kVAC Input to Output
2 kVAC Input to Baseplate
500 VDC Output to Baseplate
Switching Frequency
Parallel Operation
•
500 kHz - CPM50 & 100
370 kHz - CPM150, CPM200, 400 & 600
•
Current share pin provided on all
except 50 W models, derate max
O u tp u t
Output Voltage
•
•
See Tables
current by 10% per module
Output Voltage
Adjustment
±10% CPM50 & 100,
60-110% CPM150 ,CPM200 &
CPM400, 80-110% CPM600
En viro n m e n ta l
Operating
•
-10 °C to +85°C CPM50 & CPM100,
-20 °C to +85°C CPM150, CPM200,
CPM400 & CPM600 (baseplate)
Minimum Load
Start Up Delay
Initial Set Accuracy
Drift
•
•
•
•
•
•
•
•
No minimum load required
200 ms max (100% load)
±4.0% max
Temperature
Storage
•
-40 °C to +85 °C
±0.5% max
Temperature
Line Regulation
Load Regulation
Ripple & Noise
±0.5% max
Relative Humidity
Shock
•
•
20-95% non-condensing
±0.9% max
20 G for 11 ms once each along
X, Y & Z axis
200 mV pk-pk (0°C to +85°C)
Vibration
•
10-55 Hz 5 G for 3 min periods,
over 60 mins along each X, Y & Z axis
Overload
Protection
Operates at >105% of rated current,
recovers automatically
Overvoltage
Protection
•
•
Operates at between 115-140% of
rating recycle input to reset
S a fe ty
Emissions
•
EN55022 Level A conducted
EN55022 Level A radiated
Remote Sense
Compensates for 300mV min
if not required then sense connections
must be made locally ie +S to +Vout
and -S to -Vout
Contact sales for Application Note
ESD Susceptibility
•
EN61000-4-2 Level 2
Remote ON/OFF
•
Standard on all models
Radiated
Susceptibility
•
•
•
•
EN61000-4-3 Level 3
EN61000-4-4 Level 3
EN61000-4-5 Level 3
EFT/Burst
Surge
Safety Approvals
UL1950, C-UL, EN60950, VDE0160
IEC950
•
•
w w w .xp p lc .c o m
s a le s @xp p lc .c o m