9U Dual System CompactPCI® Chassis with
Redundant Power Supplies
cPCIS-3320 Series
Features
Standard 6U CompactPCI® and PICMG® 2.5
H.110 CT Bus for all peripheral slots
PICMG® 2.1 Hot Swap compliant 64-bit
CompactPCI® backplane with P3 & P5 rear I/O
Dual cPCI segments (System A: 1 + 7 slots,
System B: 1 + 4 slots)
3+1 (750 W + 250 W) hot swappable redundant
power supplies with universal AC input
Redundant cooling architecture
Magnetic circuit breaker protection for
AC input
Specifications
Enclosure
EIA RS-310C 19 9U high rackmount enclosure
Coated metal plate outer covering
Alarm Module
Basic Alarm
Module
Monitors inner chassis temperature,
voltage and fan status
Abnormal status will generate alarm and
LED warning
Guarded power switch and reset button
6U CompactPCI®
Form Factor
CompactPCI®
Standards
Alarm reset
2.0 R3.0, 2.1 R2.0, 2.5 R1.0, 2.7 R1.0, 2.9 R1.0, 2.11 R1.0
Drive Bay
Two 5.25 drive bays
Cooling System
Two top
blowers for
ventilation
Rated speed for each fan: 3150 RPM
Backplane
System A
64-bit/33 MHz
One
System B
64-bit/66 MHz
One
Rated power for each fan: 6.12 W
Maximum Air Flow: 21.02 CFM
(Call for Availability)
cPCI Bus
System Slot
Peripheral Slot
H.110 CT Bus
Rear I/O
One top fan
Rated speed for each fan: 4000 500 RPM
for ventilation Rated power for each fan: 2.64 W
Maximum Air Flow: 48.2 CFM
Seven
Four
Comply with all peripheral slots
All slots support P3, P4, P5 rear I/O
with AB-type shroud
Five fans for
front-access
intake
Rated speed for each fan: 4000 500 RPM
Rated power for each fan: 2.64 W
Maximum Air Flow: 48.2 CFM
V (I/O)
3.3 V or 5 V (default) selectable
One
CMM slot
Power Input
Physical
Dimensions
483.2 x 399 x 339.1 (mm, W x H x D,
w/ handle)
ATX connector x2, DC screw terminals
Power Supply
Supports current sharing on 5 V, 3.3 V and 12 V
PICMG® 2.11 47-pin power interface
Power module: cPS-H325/AC x4
Weight
24.5 kg/53.9 lbs (including redundant
power supply and backplane only)
Operating Temp.
Storage Temp.
Humidity
0˚C to 55˚C (dependent on system configurations)
-20˚C to 80˚C
Max. Load*
132.0 A
132.0 A
22.0 A
Min. Load
6.0 A
N/A
5% to 95%, non-condensing
+5 V
Shock
15 G peak-to-peak, 11 ms duration, non-operation
Non-operation: 1.88 Grms, 5-500 Hz, each axis
+3.3 V
+12 V
-12 V
Vibration
N/A
Operation: 0.5 Grms, 5-500 Hz, each axis, tested with
2.5” HDD
4.0 A
N/A
* Max. load is the continuous operating load of each rail
individually. The Max. load of each rail cannot be drawn from
all outputs simultaneously.
3-7