REVISION X
CLP-1XX-XX-XX-S-XX
No. OF POSITIONS
-02 THRU -50
OPTION
-TR: TAPE AND REEL
DO NOT
SCALE FROM
THIS PRINT
BODY SPEC
-S: SINGLE ROW
LEAD STYLE SPEC
-02: SURFACE MOUNT
(USE C-106-01-X)
(USE CLP-50-S)
C1
(NO OF POS X .0500[1.270])+.017[0.43]±.005[0.13]
PLATING SPEC
-G: 10µ" GOLD IN CONTACT AREA,
02
3µ" GOLD ON TAIL
-F: 3µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-L: 10µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
.025 0.64 REF
C-106-01-X
-FM: 3µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
01
03
.0160 0.406 x .0050[.127] REF
(NO OF POS X .0500[1.270]) - .0500[1.270] REF
C2
1
MAX SWAY
(ANY DIRECTION)
"A"
C3
.0890 2.261
.0835 2.121 REF
+3
C4
(MEASURE AT BEND)
.004[0.10 POS. 2-25
.006[0.15 POS. 26-50
"A"
-3
.119±.010 3.02±0.25
(SEE NOTE 3)
TUBE PACKAGING
SECTION "A"-"A"
SCALE 3:1
CLP-50-S
TUBE: PT-1-24-02-65
PLUG: TP-30
NOTES:
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
1. C PREPRESENTS A CRITICAL DIMENSION FOR STATISTICAL PROCESS CONTROL.
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
2. MINIMUM PUSHOUT FORCE: .5 LB.
DECIMALS
ANGLES
2
3. SHEAR TAILS TO DIMENSIONS SHOWN.
.XX: .01 [.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
DESCRIPTION:
C
4. PARTS TO BE SYMMETRICAL ABOUT
.
L
.XXX: .005 [.13]
5. WILL LOSE ONE POSITION PER CUT TO OBTAIN ODD POSITION PARTS.
WILL LOSE TWO POSITIONS PER CUT TO OBTAIN EVEN POSITION PARTS.
6. TUBE PACKAGE POSITIONS 5 THROUGH 50 ONLY. POSITIONS 2 THRU4
ARE TO BE LAYER PACKAGED.
.XXXX: .0020 [.051]
SHEET SCALE: 6:1
MATERIAL:
DO NOT SCALE DRAWING
LOW PROFILE .050 C.L. SINGLE ROW ASM.
DWG. NO.
INSULATOR: LCP, UL 94 VO, COLOR: BLACK
CONTACT: PHOS BRONZE
C6
7. .002[0.05] MAX BURR.
CLP-1XX-XX-XX-S-XX
BRATCHER 06/07/1995 SHEET 1 OF 1
C5 8. CUT FLASH TO BE .010[0.25] MAX WITH NO FLASH ALLOWED IN HOLES
OR EXTENDING BELOW LEADS.
BY:
F:\DWG\MISC\MKTG\CLP-1XX-XX-XX-S-XX-MKT.SLDDRW