100W Single Output Switching Power Supply
CLG-100 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
3 years warranty (Note.7)
110
SELV
EQUIVALENT
F
M
M
( for 48V only)
( except for 48V )
IP67
LPS
SPECIFICATION
MODEL
CLG-100-12
CLG-100-15
CLG-100-20
CLG-100-24
CLG-100-27
CLG-100-36
CLG-100-48
DC VOLTAGE
12V
15V
20V
24V
27V
36V
48V
CONSTANT CURRENT REGION Note.8 6 ~ 12V
7.5 ~ 15V
5A
10 ~ 20V
4.8A
12 ~ 24V
4A
13.5 ~ 27V
3.55A
18 ~ 36V
2.65A
24 ~ 48V
2A
RATED CURRENT
CURRENT RANGE
RATED POWER
Note.6 5A
Note.6 0 ~ 5A
Note.6 60W
0 ~ 5A
75W
0 ~ 4.8A
96W
0 ~ 4A
96W
0 ~ 3.55A
95.85W
150mVp-p
0 ~ 2.65A
95.4W
0 ~ 2A
96W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
Fixed. Can be modified between 0% ~ -15% rated output voltage
Fixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
3.0%
3.0%
3.0%
2.0%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
1.0%
2.0%
1200ms, 80ms / 230VAC
1200ms, 80ms / 115VAC at full load
30ms / 115VAC at full load
127 ~ 370VDC
60ms / 230VAC
Note.5 90 ~ 264VAC
47 ~ 63Hz
PF>0.95/230VAC
83%
PF>0.95/115VAC at full load
85% 87%
15V:0.9A/115VAC 0.45A/230VAC
INPUT
EFFICIENCY (Typ.)
AC CURRENT
87%
87%
87%
87%
12V:0.8A/115VAC 0.4A/230VAC
COLD START 40A/230VAC
0.5mA / 240VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC
INRUSH CURRENT(max.)
LEAKAGE CURRENT
95 ~ 100%
OVER CURRENT
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
Note.4
SHORT CIRCUIT
OVER VOLTAGE
13 ~ 16V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90 10 (RTH2)
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
29 ~ 36V
39 ~ 48V
52 ~ 64V
PROTECTION
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-40 ~ +80 , 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13
CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:1.5KVAC
SAFETY &
EMC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A
301Khrs min. MIL-HDBK-217F (25
222*68*39mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
1.0Kg; 12pcs/13Kg/0.49CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. 3 years warranty is guaranteed for operating ambient temperature no higher than 68
.
8. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:CLG-100-SPEC 2008-12-10