100W Single Output Switching Power Supply
CLG-100 series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage/Over temperature
Built-in active PFC function
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High realibility
Suitable for LED lighting and moving sign applications
3 years warranty (Note.7)
( for 48V only)
( except for 48V )
IP67
SPECIFICATION
MODEL
CLG-100-12
CLG-100-15
CLG-100-20
CLG-100-24
CLG-100-27
CLG-100-36
CLG-100-48
DC VOLTAGE
12V
15V
20V
24V
27V
36V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
Note.6 5A
5A
4.8A
4A
3.55A
2.65A
2A
Note.6 0 ~ 5A
Note.6 60W
0 ~ 5A
75W
0 ~ 4.8A
96W
0 ~ 4A
96W
0 ~ 3.55A
95.85W
150mVp-p
0 ~ 2.65A
95.4W
0 ~ 2A
96W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
Fixed. Can be modified between 0% ~ -15% rated output voltage
Fixed. Can be modified between 3% ~ -25% rated output current
OUTPUT
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
3.0%
3.0%
3.0%
2.0%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
1.0%
2.0%
1200ms, 80ms / 230VAC
1200ms, 80ms / 115VAC at full load
60ms / 230VAC
Note.5 90 ~ 264VAC
47 ~ 63Hz
30ms / 115VAC at full load
PF>0.95/230VAC
83%
PF>0.98/115VAC at full load
85% 87%
15V:0.9A/115VAC 0.45A/230VAC
INPUT
EFFICIENCY (Typ.)
AC CURRENT
87%
87%
87%
87%
12V:0.8A/115VAC 0.4A/230VAC
COLD START 40A/230VAC
0.5mA / 240VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC
INRUSH CURRENT(max.)
LEAKAGE CURRENT
95 ~ 100%
OVER CURRENT
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 29 ~ 36V 39 ~ 48V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90 10 (RTH2)
52 ~ 64V
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70 (Refer to output load derating curve), -40 possible
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
UL1310 Class 2, TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V),IP67 Approved
I/P-O/P:4.25KVDC
SAFETY &
EMC
I/P-O/P:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
301Khrs min. MIL-HDBK-217F (25
222*68*39mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
1.0Kg; 12pcs/13Kg/0.49CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. 3 years warranty is guaranteed for operating ambient temperature no higher than 68
.
File Name:CLG-100-SPEC 2006-08-30