C5379
VCXO
Typical Applications
Telecommunication
Features
Standard 4-Pin DIP Package (Half Size)
Wireless Application
BB
Previous Vectron Model Numbers
Frequency range
1 MHz – 125 MHz
Frequency stabilities1
Operating temp
range
Parameter
Min
Typ
Max.
Units
Ordering Code5
Overall (vs. Initial, vs. operating
temperature range vs. supply voltage
change vs. load change
-100.0
-50.0
-25.0
-100.0
-50.0
-32.0
+100.0
+50.0
+25.0
+100.0
+50.0
+32.0
ppm
ppm
ppm
ppm
ppm
ppm
-0 … +70°C
-0 … +70°C
-0 … +70°C
-40 … +85°C
-40 … +85°C
-40 … +85°C
C104
C505
C255
F104
F505
F325
vs. aging /1. Yea)r
Supply voltage
Parameter
Min
Typ
Max.
Units
Condition
Ordering Code5
Supply voltage (Vs)
4.75
5.0
5.25
VDC
SV050
Current consumption
40
50
55
mA
@ HCMOS fo < 24.0 MHz
@ HCMOS fo < 50.0 MHz
@ HCMOS fo < 70.0 MHz
@ HCMOS fo < 100.0 MHz
70
Supply voltage (Vs)
Current consumption
3.135
3.3
3.465
VDC
mA
SV050
30
35
40
50
@ HCMOS fo < 24.0 MHz
@ HCMOS fo < 50.0 MHz
@ HCMOS fo < 70.0 MHz
@ HCMOS fo < 100.0 MHz
RF output
Parameter
Signal
Min
Typ
Max.
HCMOS
Units
Condition
Ordering Code5
RFH
Load
15.0
pF
Rise and Fall time
Duty cycle
10
60
ns
%
@ 15 pF 10 to 90 %
40
@ Vs/2
Frequency Tuning (EFC)
Parameter
Tuning Range
Min
±50.0
±100.0
Typ
±90.0
±140.0
Max.
+200.0
±200.0
10
Units
ppm
ppm
%
Condition
Linearity
Tuning Slope
Positive
Control Voltage Range
0.0
0.5
10
1.65
2.5
3.3
4.5
VDC
VDC
k Ω
with Vs=3.3VDC
with Vs=5.0VDC
Frequency control input impedance
v.2005-02-10 · page 1 of 3
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
USA
+86 21 28909740 tel.
+86 21 28909240 fax
+1-717-486-3411 tel
+1-717-486-5920 fax