5秒后页面跳转
C08DRT PDF预览

C08DRT

更新时间: 2024-11-28 12:53:35
品牌 Logo 应用领域
芯科 - SILICON /
页数 文件大小 规格书
3页 570K
描述
INSULATOR MATERIAL: SEEPART NUMBER CODING

C08DRT 数据手册

 浏览型号C08DRT的Datasheet PDF文件第2页浏览型号C08DRT的Datasheet PDF文件第3页 
4
1
8
7
5
3
2
6
REVISIONS  
REV. ECO. NO  
DESCRIPTION  
INITIAL RELEASE  
DATE  
BY  
MNH  
JH  
A
B
1254  
2072  
1-25-07  
11/05/09  
ADD B MOUNTING STYLE  
E
D
B
A
F
F
E
E
.100 2.54  
.075[1.90]  
CARDSLOT  
2X .125 3.18  
C
.265 6.73  
INSERTION  
DEPTH  
F
.186 4.72  
A
D
D
.431 10.95  
.200±.025 5.08±0.64  
TAIL LENGTH  
.245 6.22  
.025 0.64  
.140 3.56  
ROW SPACING  
FITS .043 MIN HOLE  
C
C
A
_ _ C _ _ DRTH  
SECTION A - A  
CONTACT MARKINGS  
B 1 2 3 ... 60 B  
A 1 2 3 ... 60 A  
B
B
NOTES:  
1. INSULATOR MATERIAL: SEE PART NUMBER CODING  
2. CONTACT MATERIAL: SEE PART NUMBER CODING  
3. PLATING: SEE PART NUMBER CODING  
4. OPERATING TEMPERATURE: SEE PART NUMBER CODING  
5. PROCESSING TEMP: SEE PART NUMBER CODING  
6. UL FLAMMABILITY RATING: 94V-0  
CONTACT ID  
SCALE 2:1  
7. VOLTAGE RATING: 600 VDC MINIMUM AT SEA LEVEL.  
8. CURRENT RATING: 3 AMP PER CONTACT PAIR  
9. VOLTAGE DROP: 30 MILLI VOLT AT RATED CURRENT  
10. INSULATION RESISTANCE: 5000 MEGA OHM  
CUSTOMER COPY  
DATE  
NAME  
UNLESS OTHERWISE SPECIFIED:  
DRAWN  
MNH  
DIMENSIONS ARE IN INCHES[MM]  
1/25/07  
TOLERANCES:  
THE INFORMATION HEREIN CONTAINS  
PROPIETARY INFORMATION OF  
ANGULAR: 30'  
11. CONNECTOR IDENTIFICATION: THE PART SHALL BE MARKED WITH A PART  
NUMBER AND BARCODE  
A
DESCRIPTION  
SULLINS ELECTRONICS AND IS NOT  
TO BE REPRODUCED, USED OR  
DISCLOSED TO OTHERS FOR ANY  
PURPOSE EXCEPT AS SPECIFICALLY  
AUTHORIZED IN WRITING BY AN  
OFFICER OF SULLINS ELECTRONICS.  
.XX= .02 [.508]  
A
EDGECARD, .100 CC LP  
PART NUMBER  
_ _C_ _DRT_  
.XXX= .005 [.1270]  
Pb  
oHS COMPLIANT  
.XXXX= .0005 [.0127]  
SURFACE FINISH: 63 Ra  
REMOVE ALL BURRS AND SHARP EDGES .010 MAX  
12. BOARD THICKNESS ACCOMMODATED: .062 .008"  
13. BOARD INSERTION FORCE: 16 OZ MAX PER CONTACT PAIR WHEN USING A .062" TEST BLADE.  
INTERNAL INSPECTION TO BE PER SULLIN'S WORK INSTRUCTION W17.3-01.  
C DWG. NO.  
SIZE  
REV  
B
INTERPRET DIMENSIONS AND GEOMETRIC  
TOLERANCING  
C10878  
14. BOARD WITHDRAWAL FORCE: 1 OUNCE MINIMUM PER CONTACT PAIR USING .062" PCB  
PER: ANSI Y14.5M-1994  
R
SCALE: 2:1  
SHEET 1 OF 3  
1
4
8
7
6
5
3
2
FILE NAME: Z:\ECO PENDING\2072\C10878, _ _C_ _DRT_ PRINT: 1/28/2010  

与C08DRT相关器件

型号 品牌 获取价格 描述 数据表
C08DRX SILICON

获取价格

BOARD INSERTION FORCE: 16 OZ MAX PER CONTACT PAIR WHEN USING A .062 TEST BLADE
C08DRY SILICON

获取价格

PLATING: SEE PART NUMBER CODING OPERTING
C08E ETC

获取价格

high voltage CMOS process
C08G0.5 COOPER

获取价格

Circuit Protection Solutions Low Voltage Fuse Links Catalogue
C08G0-5 COOPER

获取价格

Cylindrical fuse links
C08G1 COOPER

获取价格

Circuit Protection Solutions Low Voltage Fuse Links Catalogue
C08G10 COOPER

获取价格

Circuit Protection Solutions Low Voltage Fuse Links Catalogue
C08G10I COOPER

获取价格

Circuit Protection Solutions Low Voltage Fuse Links Catalogue
C08G12 COOPER

获取价格

Circuit Protection Solutions Low Voltage Fuse Links Catalogue
C08G12I COOPER

获取价格

Circuit Protection Solutions Low Voltage Fuse Links Catalogue