描述
Design Note 100 Rev. 01 - Feb. 1999

BXA15 数据手册

 浏览型号BXA15的Datasheet PDF文件第2页浏览型号BXA15的Datasheet PDF文件第3页浏览型号BXA15的Datasheet PDF文件第4页 
BXA15 and BXA30 SERIES  
Design Note 100 Rev. 01 - Feb. 1999  
Safe ty and the low voltage dire ctive  
• Ele ctromagne tic Compatibility Immunity  
• Ele ctromagne tic Compatibility Conducte d and  
Radiate d Inte rfe re nce  
• Te le com and Dis tribute d Powe r Archite cture Fe ature s  
Sys te m Prote ction Fe ature s  
• The rmal Cons ide rations  
• Input Impe dance Cons ide rations  
1. Safety and the Low Voltage Directive  
Conducted Interference - Level B External Filter:  
The BXA15 and BXA30 series is intended to be supplied only from a  
SELV (Safe Extra Low Voltage) circuit or a TNV (Telecommunications  
Network Voltage) power source which are insulated from the AC  
mains by reinforced insulation. Basic isolation, tested to 1,500VDC,  
for EN60950 and UL1950, is provided.  
The addition of an external capacitor enables the BXA15 and  
BXA30 products to meet VDE0871/8-B, EN55022-B and CISPR22-B  
conducted noise limits. The test set-up is per VDE 0877 Part 1 fig.4  
with the load < 10 cm's away from the test converter.  
Input Voltage  
Recommended External Cap.  
SELV  
TNV  
DC Distributed Power of 12V, 24V or 48V  
Central Office -48V  
48 Volt  
Nippon Chemi-Con SXE series120uF, 100V  
ITW PAKTRON Capstick series part number  
405K100CS4, 4uF @ 100V  
24 Volt  
12 Volt  
ITW PAKTRON 405K100CS4  
2 * ITW PAKTRON 405K100CS4  
capacitors in close parallel.  
2. Electromagnetic Compatibility Immunity  
Good design practice dictates that the electronic system be immune  
to noise interference. This practice has now been encapsulated in  
European law in the form of the EMC directive. It is imperative that  
any system on sale in the European Union meets the terms of the  
EMC directive and thus carries the CE mark. To simplify system  
compliance to the EMC Directive, the BXA15 and BXA30 have been  
designed to meet and comply with the necessary immunity stan-  
dards.  
For height critical applications, the ITW Paktron capacitor offers a  
low profile of <7mm.  
Note on the test set up and system grounding:  
The products meet input conducted noise VDE0878-B, EN55022-B  
and CISPR22-B 10kHz - 30MHz, if the load is not more than 10  
cm's away. Tightly parallel tracks or twisted pair wiring to the load  
should be used. Long leads to the load could radiate common  
mode noise, typically above 20 MHz, back to the input power leads.  
Conducted emissions should be checked at a system level.  
If the unit fails level B at a frequency greater then 20MHz, because  
of system wiring, an additional external Y-capacitor’ could be con-  
nected between input ground and output common, to locally  
decouple common-mode noise. This capacitor type is usually  
intended for use in interference suppression between line and earth.  
A recommended capacitor is EVOX-RIFA PME271Y422M or equiva-  
lent.  
Description  
Standard  
Compliance Level  
Electro-Static  
Discharge  
EN61000-4-2  
4kV Contact  
8kV Discharge  
Radiated Immunity  
IEC801-3  
10V/m  
2kV  
Fast Transients/Bursts  
Surges  
EN61000-4-4  
EN61000-4-5  
0.5KV (40 Ohm  
Generator,  
Secondary surge  
protection)  
4. Telecom and Distributed Power Architecture  
Features  
3. Electromagnetic Compatibility Conducted and  
Radiated Interference  
Input Undervoltage Protection:  
Internally, the BXA15 and BXA30 series contain an undervoltage  
lockout zener circuit. The converter should not be operated continu-  
ously at levels between the maximum guaranteed-off-threshold’  
and the minimum guaranteed-on-threshold.’  
Radiated Interference:  
The BXA15 and BXA30 series meet the harmonised standard  
EN55022 level A and CISPR22 level A. The series almost meets the  
requirements of level B. System performance to level B could be  
assured with the appropriate enclosure.  
Nominal Input  
Voltage  
Maximum Off  
Voltage  
Minimum On  
Voltage  
Conducted Interference - Level A Internal Filter Option:  
All three input voltage versions of the series, 12VDC, 24VDC and  
48VDC, are available with an internal filter option which meets input  
conducted noise per VDE0871/8-A or EN55022-A. To order a model  
with the internal filter, add -F’ after the model number eg. BXA15-  
48S12-F.  
12  
24  
48  
7.0  
14  
28  
8.8  
17  
34  
PAGE 1  

与BXA15相关器件

型号 品牌 获取价格 描述 数据表
BXA15-12D12 ETC

获取价格

Analog IC
BXA15-12D12F ETC

获取价格

Analog IC
BXA15-12S05 ETC

获取价格

Analog IC
BXA15-12S05F ETC

获取价格

Analog IC
BXA15-12S12 ETC

获取价格

Analog IC
BXA15-12S12F ETC

获取价格

Analog IC
BXA15-12S15 ETC

获取价格

Analog IC
BXA15-12S15F ETC

获取价格

Analog IC
BXA15-24D12 ETC

获取价格

Analog IC
BXA15-24D12F ETC

获取价格

Analog IC