5秒后页面跳转
BU52056NVX PDF预览

BU52056NVX

更新时间: 2024-02-20 22:00:13
品牌 Logo 应用领域
罗姆 - ROHM 传感器换能器磁场传感器输出元件
页数 文件大小 规格书
32页 601K
描述
Omnipolar Detection Hall ICs

BU52056NVX 技术参数

是否Rohs认证: 符合生命周期:Obsolete
Reach Compliance Code:compliant风险等级:5.83
Is Samacsys:N其他特性:SEATED HEIGHT-MAX
主体宽度:1.2 mm主体高度:0.6 mm
主体长度或直径:1.6 mm滞后:0.8 mT
最大磁场范围:6.4 mT最小磁场范围:2 mT
安装特点:SURFACE MOUNT最大工作电流:0.008 mA
最高工作温度:85 °C最低工作温度:-40 °C
输出范围:0.20-1.60V输出类型:VOLTAGE OUTPUT
封装形状/形式:RECTANGULAR传感器/换能器类型:MAGNETIC FIELD SENSOR,HALL EFFECT
最大供电电压:3.6 V最小供电电压:1.65 V
表面贴装:YES端接类型:SOLDER
Base Number Matches:1

BU52056NVX 数据手册

 浏览型号BU52056NVX的Datasheet PDF文件第25页浏览型号BU52056NVX的Datasheet PDF文件第26页浏览型号BU52056NVX的Datasheet PDF文件第27页浏览型号BU52056NVX的Datasheet PDF文件第29页浏览型号BU52056NVX的Datasheet PDF文件第30页浏览型号BU52056NVX的Datasheet PDF文件第31页 
BU52001GUL,BU52011HFV,BU52021HFV,BU52015GUL,BU52025G,BU52051NVX,  
BU52053NVX,BU52054GWZ,BU52055GWZ,BU52056NVX,BU52061NVX,BD7411G  
Technical Note  
Notes for use  
1) Absolute maximum ratings  
Exceeding the absolute maximum ratings for supply voltage, operating conditions, etc. may result in damage to or  
destruction of the IC. Because the source (short mode or open mode) cannot be identified if the device is damaged in this  
way, it is important to take physical safety measures such as fusing when implementing any special mode that operates in  
excess of absolute rating limits.  
2) GND voltage  
Make sure that the GND terminal potential is maintained at the minimum in any operating state, and is always kept lower  
than the potential of all other pins.  
3) Thermal design  
Use a thermal design that allows for sufficient margin in light of the power dissipation (Pd) in actual operating conditions.  
4) Pin shorts and mounting errors  
Use caution when positioning the IC for mounting on printed circuit boards. Mounting errors, such as improper positioning  
or orientation, may damage or destroy the device. The IC may also be damaged or destroyed if output pins are shorted  
together, or if shorts occur between the output pin and supply pin or GND.  
5) Positioning components in proximity to the Hall IC and magnet  
Positioning magnetic components in close proximity to the Hall IC or magnet may alter the magnetic field, and therefore  
the magnetic detection operation. Thus, placing magnetic components near the Hall IC and magnet should be avoided in  
the design if possible. However, where there is no alternative to employing such a design, be sure to thoroughly test and  
evaluate performance with the magnetic component(s) in place to verify normal operation before implementing the design.  
6) Slide-by position sensing  
Fig.73 depicts the slide-by configuration employed for position sensing. Note that when the gap (d) between the magnet  
and the Hall IC is narrowed, the reverse magnetic field generated by the magnet can cause the IC to malfunction. As seen  
in Fig.74, the magnetic field runs in opposite directions at Point A and Point B. Since the bipolar detection Hall IC can  
detect the S-pole at Point A and the N-pole at Point B, it can wind up switching output ON as the magnet slides by in the  
process of position detection. Fig. 75 plots magnetic flux density during the magnet slide-by. Although a reverse magnetic  
field was generated in the process, the magnetic flux density decreased compared with the center of the magnet. This  
demonstrates that slightly widening the gap (d) between the magnet and Hall IC reduces the reverse magnetic field and  
prevents malfunctions.  
10  
8
Reverse  
Magnetic  
Field  
Magnet  
Slide  
6
4
Magnetic Flux  
2
0
-2  
-4  
-6  
-8  
-10  
A
S
B
Hall IC  
L
Magnetic Flux  
0
1
2
3
4
5
6
7
8
9
10  
N
Fig.74  
Horizontal distance from the magnet [mm]  
Fig.75  
Fig.73  
7) Operation in strong electromagnetic fields  
Exercise extreme caution about using the device in the presence of a strong electromagnetic field, as such use may cause  
the IC to malfunction.  
8) Common impedance  
Make sure that the power supply and GND wiring limits common impedance to the extent possible by, for example,  
employing short, thick supply and ground lines. Also, take measures to minimize ripple such as using an inductor or  
capacitor.  
9) GND wiring pattern  
When both a small-signal GND and high-current GND are provided, single-point grounding at the reference point of the set  
PCB is recommended, in order to separate the small-signal and high-current patterns, and to ensure that voltage changes  
due to the wiring resistance and high current do not cause any voltage fluctuation in the small-signal GND. In the same  
way, care must also be taken to avoid wiring pattern fluctuations in the GND wiring pattern of external components.  
10)Exposure to strong light  
Exposure to halogen lamps, UV and other strong light sources may cause the IC to malfunction. If the IC is subject to such  
exposure, provide a shield or take other measures to protect it from the light. In testing, exposure to white LED and  
fluorescent light sources was shown to have no significant effect on the IC.  
11)Power source design  
Since the IC performs intermittent operation, it has peak current when it’s ON. Please taking that into account and under  
examine adequate evaluations when designing the power source.  
www.rohm.com  
2010.12 - Rev.F  
28/31  
© 2010 ROHM Co., Ltd. All rights reserved.  

与BU52056NVX相关器件

型号 品牌 描述 获取价格 数据表
BU52058GWZ-E2 ROHM Hall Effect Sensor, 0.6mT Min, 5mT Max, 0.2-1.6V, Square, Surface Mount, UCSP-4

获取价格

BU52061NVX ROHM Omnipolar Detection Hall ICs

获取价格

BU52061NVX-TR ROHM Hall Effect Sensor, 1.2mT Min, 4.7mT Max, 0.20-1.60V, Bipolar, Plastic/epoxy, Rectangular,

获取价格

BU52069GWZ ROHM Unipolar Detection Hall IC

获取价格

BU52069GWZ-E2 ROHM Unipolar Detection Hall IC

获取价格

BU52072GWZ ROHM 双极检测(极性判别输出)霍尔IC BU52072GWZ具备S极检测用和N极检测用2种输出,

获取价格