VER : A_1
update : 2015.03.16
DC-DC Brick
BR400 SERIES
400 Watts
DESCRIPTION
KEY FEATURES
Input under Voltage Protection
Over Current Protection (Hiccup Mode)
Short Circuit Protection (Hiccup Mode)
Over Voltage Protection (Hiccup Mode)
Over Temperature Protection (Self-recovery)
Activates Hardware and Software *
Digitally Adjusts the Voltage *
The BR400 is an isolated DC-DC converter that uses an industry nonstandard
quarter-brick structure and features high efficiency and power density.
It provides 12 V outputs and supports the maximum output current of 33 A.
Two BR400s can be connected in parallel to provide the maximum output
current of 54 A.
The BR400 communicates over PMBus 1.1 to support monitoring and alarm
reporting functions, such as monitoring the output voltage and current, input
voltage, digitally adjusting the voltage, and activating software.
PMBus Revision 1.1 compliant *
Secondary ON/OFF Control *
Pre-Bias Function *
Peak Efficiency:96%(12V,16.5A)
UL60950-1 and CSA C22.2 No. 60950-1-07
Meet UL94V-0 Flammability Requirements
Rohs6 Compliant
Size: 2.28 x 1.45 x 0.5 Inches
3-Years Product Warranty
*BR400-12S without this function
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1.5 m/s (300 LFM), Vin = 48 V, unless otherwise notes.
Model No.
BR400-12S
BR400-12S-P
Max Output Wattage (W)
396W
Voltage (V.DC.)
48V (36~72V)
Current (A) (max)
14A (Vin= 36 - 72 V; Iout = 33 A)
3W (Vin= 48 V; Iout = 0 A)
200 mA (Oscilloscope Bandwidth:20 MHz)
12V
Input
No-Load Loss (W) (typ.)
Reflected Ripple Current (peak to peak) (typ.)
Voltage (V.DC.)
11.64~12.36V
Voltage Range (V.DC.)
11.64~12.36V (Vin= 40 - 72 V)
10.8~12.36V (Vin= 36 - 40 V)
(Vin= 40 - 75 V; Adjust the voltage by PMBus)
10.8~12.36V
(Vin= 36 - 40 V; Adjust the voltage by PMBus)
Voltage Trim Range (V.DC.)
Current (A) (max.)
8.4~12V
33A
Output
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
Efficiency
0.2% (Vin= 40 - 72 V; Iout = 33 A) / 10% (Vin= 36 - 40 V; Iout = 33 A)
3% (Vin = 48 V; Iout = 0 - 33 A)
200 mV (Oscilloscope Bandwidth:20 MHz)
100% Load:95% (Iout = 33 A)
50% Load:96% (Iout = 16.4 A)
100% Load:94% (Iout = 6.6 A)
Hiccup mode
(Vin = 48 V; TA=25°C (77°F)) (typ.)
Over Power Protection
Over Current Protection
Over Voltage Protection
Short Circuit Protection (max.)
Over Temperature Protection
Hiccup mode
14~16V (Hiccup mode)
Hiccup mode
Threshold:115~135°C / Hysteresis:10~20°C
Protection
Self-recovery (The values are obtained by measuring the temperature of the hottest power
component on the top surface of the converter.)
Isolation
Voltage (V.DC.)
1500 VDC (Functional Isolation)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
Environment
MTBF
1.5 Million Hours
(Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F)
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
Safety
EMC
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Weight
2.28 x 1.45 x 0.5 Inches ( 57.9 x 36.8 x 12.7 mm ) Tolerance 0.5 mm
66 g
Physical
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-