Inductive Sensors
BES 516-3022-G-E4-C-PU-05
Order Code: BES00L3
1) Sensing surface
Basic features
Electrical data
Approval/Conformity
cULus
CE
Load capacitance max. at Ue
Min. operating current Im
1 µF
0 mA
2 mA
EAC
No-load current Io max., damped
WEEE
No-load current Io max., undamped 6 mA
Basic standard
IEC 60947-5-2
Operating voltage Ub
10...30 VDC
Output resistance Ra
Open drain
75 V DC
100 mA
24 V
Display/Operation
Rated insulation voltage Ui
Rated operating current Ie
Rated operating voltage Ue DC
Rated short circuit current
Ready delay tv max.
Function indicator
Power indicator
yes
no
100 A
21 ms
10 µA
Electrical connection
Residual current Ir max.
Ripple max. (% of Ue)
Switching frequency
Cable diameter D
3.00 mm
10 %
Cable length L
5 m
5000 Hz
DC -13
2 V
Conductor cross-section
Connection type
0.14 mm²
Utilization category
Cable, 5.00 m, PUR
Voltage drop static max.
Number of conductors
Polarity reversal protected
Protection against device mix-ups
Short-circuit protection
3
yes
yes
yes
Environmental conditions
Ambient temperature
Contamination scale
EN 60068-2-27, Shock
EN 60068-2-6, Vibration
Protection degree
-25...70 °C
3
Half-sinus, 30 gn, 11 ms
55 Hz, amplitude 1 mm, 3x30 min
IP67
Functional safety
MTTF (40 °C)
305 a
1 / 2
Internet
www.balluff.com
eCl@ss 9.1: 27-27-01-01
Subject to change without notice: 235781
ETIM 6.0: EC002714
BES00L3_0.62_2020-08-04