200-400 Watts
BCC Series
xppower.com
•
•
•
•
•
•
•
Baseplate-cooled
Wide Operating Temperature Range
ETSI, EMC and Environmental Compliant
Parallel Operation
Active PFC
Remote On/Off
Low Temperature Option
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
Efficiency
Isolation
• 80% typꢀcal
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 3 A max at 90 VAC (BCC200)
6 A max at 90 VAC (BCC400)
Switching Frequency
MTBF
• PWM 360 kHz typ, PFC 90 kHz typ
Inrush Current
Power Factor
• 60 A at 264 VAC +25 ºC cold start
• >0.9
• 160 kHrs per MIL-HDBK-217F at 25 ºC
Earth Leakage Current • <1.5 mA at 230 VAC
Environmental
Input Protection
• Internal 10 A fuse
Operating Temperature • -20 ºC to +70 ºC, wꢀth baseplate
maꢀntaꢀned below +83 ºC utꢀlꢀzꢀng system
coolꢀng, -40 ºC optꢀon avaꢀlable - add
Output
Output Power
• See table
suffꢀx ‘L’ to model number
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Hold Up Time
• See table
Cooling
• Conductꢀon vꢀa 6mm baseplate
• 60% to 110% Vnom
Operating Humidity
• 20-95% RH, non-condensꢀng. Unꢀts can
be conformally coated for hꢀgh humꢀdꢀty
envꢀronments - add suffꢀx ‘E’
•
1% nomꢀnal
• No mꢀnꢀmum load
• 10 ms mꢀn
Storage Temperature
Shock & Vibration
• -40 ºC to +85 ºC
• 2 g 10 mꢀn/1 cycle, 10 Hz to 500 kHz,
60 mꢀns each axꢀs
Line Regulation
Load Regulation
Ripple & Noise
•
0.5%
• See table
• <1% pk-pk, 20 MHz bandwꢀdth
EMC & Safety
Overvoltage Protection • 105-140% Vnom
(3.3 V versꢀon 130-166%)
Emissions
• EN55022, level B conducted &
level A radꢀated
Overtemperature
Protection
• Shuts down at +115 ºC baseplate
temperature wꢀth auto recovery
Harmonic Currents
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-2, EN61000-3-3
• EN61000-4-2, level 3 Perf Crꢀterꢀa A
• EN61000-4-3, 3 V/m Perf Crꢀterꢀa A
• EN61000-4-4, level 3 Perf Crꢀterꢀa A
• EN61000-4-5, level 3 Perf Crꢀterꢀa A
• EN61000-4-6, level 3 Perf Crꢀterꢀa A
Overload Protection
• 102-140% constant current lꢀmꢀtꢀng wꢀth
auto recovery
Temperature
Coefficient
• 0.05%/ºC
Surge
Remote Sense
• Compensates for lead drops of up to
500 mV
Conducted Immunity
Dips & Interruptions
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Crꢀterꢀa A, B, B
Remote On/Off
• A logꢀc ‘0’ on the Remote On/Off
connectꢀon electronꢀcally dꢀsables
the output
Safety Approvals
• UL60950-1:2003,
Current Share
• Up to 3 power supplꢀes can be connected
ꢀn parallel sharꢀng wꢀthꢀn 10%, total output
power derates by 10%
CSA22.2 No. 60950-1-03, CE Mark LVD
EN60950-1:2001