Limit Alarms (potentiometer adj.) A-UNIT

ASP-2123-D 数据手册

 浏览型号ASP-2123-D的Datasheet PDF文件第2页浏览型号ASP-2123-D的Datasheet PDF文件第3页浏览型号ASP-2123-D的Datasheet PDF文件第4页 
MODEL: ASP  
Limit Alarms (potentiometer adj.) A-UNIT  
[3] SETPOINT 2 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
FREQUENCY ALARM  
(50 Hz minimum)  
Functions & Features  
• Providing SPDT relay outputs at preset frequency levels  
• Dual (Hi/Lo) trip  
[4] POWER INPUT  
AC Power  
• Low-end cutout  
• Energized or de-energized coil at a tripped condition  
selectable  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
• Deadband (hysteresis) adjustable  
• Enclosed relays  
• Relays can be powered 110 V DC  
• High-density mounting  
Typical Applications  
• Annunciator  
DC Power  
S: 12 V DC  
• Various alarm applications  
R: 24 V DC  
V: 48 V DC  
P: 110 V DC  
50  
(1.97)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
80  
(3.15)  
Connection: M3.5 screw terminals  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output 1 to output 2 to power  
Zero adjustment: -5 to +5 % (front)  
132  
(5.20)  
Span adjustment: 95 to 105 % (front)  
Setpoint adjustments: 270°-turn screwdriver adjustments  
(front); 0 – 100 % independently  
mm (inch)  
Remark: The ASP has low-end cutout function below 2 – 5 %  
input. A setpoint below this equals 0 %.  
Hysteresis (deadband) adjustments: 1 – 100 % (front)  
Front LEDs: LED turns on at a tripped condition; red for  
output 1, green for output 2  
MODEL: ASP-[1]1[2][3]-[4]  
ORDERING INFORMATION  
• Code number: ASP-[1]1[2][3]-[4]  
Specify a code from below for each of [1] through [4].  
(e.g. ASP-1111-B)  
Power ON timer: Relays de-energized for approx. 2 seconds  
after power is turned on.  
• Frequency range (e.g. 0 – 500 Hz)  
Low-end cutout: 2 to 5 %  
INPUT SPECIFICATIONS  
[1] INPUT  
1: Dry contact  
2: Voltage pulse  
Frequency range: 0 – 50 Hz through 10 kHz  
Pulse width (time) requirement: Duty ratio 20 – 80 % at 100  
% input  
Dry Contact: Mechanical contact or open collector  
Sensing: Approx. 7.5 V DC @1 mA  
[2] SETPOINT 1 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
ON/OFF level: ≤ 200 Ω / 0.6 V for ON, ≥ 100 kΩ / 2 V for OFF  
Voltage Pulse: Square or sine waveforms  
Input pulse sensing: Capacitor coupled; detecting pulse rise  
Input amplitude: 2 – 50 Vp-p  
Input impedance: 100 kΩ min.  
ASP SPECIFICATIONS  
ES-2156 Rev.5 Page 1/4  
http://www.m-system.co.jp/  

与ASP-2123-D相关器件

型号 品牌 获取价格 描述 数据表
ASP-2123-E MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-2123-F MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-2123-G MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-2123-H MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-2123-J MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-2123-P MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-2123-R MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-2123-S MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-2123-V MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
ASP-2124-B MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT