150W Single Output with PFC Function
ASP-150 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
High power density 8.4w/in3
100% full load burn-in test
No load power consumption<1W@240VAC
ZCS/ZVS technology to reduce power dissipation
3 years warranty
SPECIFICATION
MODEL
ASP-150-12
ASP-150-15
ASP-150-20
ASP-150-24
ASP-150-48
DC VOLTAGE
12V
15V
20V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
11A
9.5A
7.5A
6.3A
3.2A
0 ~ 11A
132W
0 ~ 9.5A
142.5W
180mVp-p
14 ~ 17V
0 ~ 7.5A
150W
0 ~ 6.3A
151.2W
240mVp-p
22 ~ 27V
0 ~ 3.2A
153.6W
240mVp-p
45.6 ~ 52.8V
RIPPLE & NOISE (max.) Note.2 150mVp-p
200mVp-p
17 ~ 22V
11 ~ 13.2V
OUTPUT
VOLTAGE ADJ. RANGE
Fixed. Can be modified between the range above by factory
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
0.5%
1.0%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
0.5%
1.0%
3000ms, 80ms at full load
50ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
16ms/115VAC at full load
127 ~ 370VDC
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF 0.95/230VAC
88%
PF 0.98/115VAC at full load
INPUT
88%
1A/230VAC
90%
90%
89%
2A/115VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
COLD START 80A/230VAC
<2mA / 240VAC
LEAKAGE CURRENT
105 ~ 135% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
13.7 ~ 16.2V
17.5 ~ 20.25V 22.5 ~ 28V 27.5 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
90 10 (RTH2) detect on heatsink of power transistor
53.3 ~ 64.8V
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) approved
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:4.25KVDC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
149.3Khrs min. MIL-HDBK-217F (25
169*60.7*28.5mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.32Kg; 48pcs/15.8Kg/0.79CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS3 & HS2,HS3 can not be shorted.
File Name:ASP-150-SPEC 2010-10-18