5秒后页面跳转
APTE-1123-H PDF预览

APTE-1123-H

更新时间: 2024-11-03 02:05:35
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
4页 125K
描述
Limit Alarms (potentiometer adj.) A-UNIT

APTE-1123-H 数据手册

 浏览型号APTE-1123-H的Datasheet PDF文件第2页浏览型号APTE-1123-H的Datasheet PDF文件第3页浏览型号APTE-1123-H的Datasheet PDF文件第4页 
MODEL: APTE  
Limit Alarms (potentiometer adj.) A-UNIT  
[3] SETPOINT 2 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
PT ALARM  
(RMS sensing)  
Functions & Features  
• Providing SPDT relay outputs at preset AC voltage levels  
from a VT  
[4] POWER INPUT  
AC Power  
• RMS sensing  
• Dual (Hi/Lo) trip  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
• Energized or de-energized coil at a tripped condition  
selectable  
• Hysteresis (deadband) adjustable  
• Enclosed relays  
• Relays can be powered 110 V DC  
• High-density mounting  
DC Power  
Typical Applications  
• Annunciator  
S: 12 V DC  
R: 24 V DC  
• Various alarm applications  
V: 48 V DC  
P: 110 V DC  
50  
(1.97)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3.5 screw terminals  
80  
(3.15)  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output 1 to output 2 to power  
Input waveform: Up to 15 % of 3rd harmonic content  
Zero adjustment: -5 to +5 % (front)  
132  
(5.20)  
Span adjustment: 95 to 105 % (front)  
mm (inch)  
Setpoint adjustments: 270°-turn screwdriver adjustments  
(front); 0 – 100 % independently  
Hysteresis (deadband) adjustments: 1 – 100 % (front)  
Front LEDs: LED turns on at a tripped condition; red for  
output 1, green for output 2  
MODEL: APTE-[1]1[2][3]-[4]  
ORDERING INFORMATION  
• Code number: APTE-[1]1[2][3]-[4]  
Specify a code from below for each of [1] through [4].  
(e.g. APTE-1111-B)  
Power ON timer: Relays de-energized for approx. 2 seconds  
after power is turned on.  
INPUT SPECIFICATIONS  
Frequency: 50 or 60 Hz  
[1] INPUT  
Voltage  
Input burden: 0.5 VA max.  
Overload capacity: 200 % of rating for 1 minute, 120 %  
continuous  
1: 0 – 110 V AC  
2: 0 – 220 V AC  
5: 0 – 150 V AC  
6: 0 - 300 V AC  
Operational range: 0 – 100 % of rating  
[2] SETPOINT 1 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
APTE SPECIFICATIONS  
ES-0235 Rev.2 Page 1/4  
http://www.m-system.co.jp/  

与APTE-1123-H相关器件

型号 品牌 获取价格 描述 数据表
APTE-1123-J MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
APTE-1123-P MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
APTE-1123-R MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
APTE-1123-S MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
APTE-1123-V MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
APTE-1124-B MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
APTE-1124-C MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
APTE-1124-D MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
APTE-1124-F MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
APTE-1124-G MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT