8-ch RTD Module
APAX-5013
APAX-5017
APAX-5018
12-ch Analog Input Module
12-ch Thermocouple Input Module
NEW
NEW
RoHS
COMPLIANT
2002/95/EC
RoHS
2002/95/EC
COMPLIANT
APAX-5013
APAX-5017
APAX-5018
Specifications
Specifications
General
General
Dimensions (W x H x D) 30 x 139 x 100 mm
Dimensions (W x H x D) 30 x 139 x 100 mm
Weight
Power Consumption
Weight
170 g
Power Consumption
(typical)
4 W @ 24 VDC (APAX-5017)
3.5 W @ 24 VDC (APAX-5018)
170 g
2.5 W @ 24 VDC (typical)
Analog Input
Channels
Input Type
12 (Differential)
V, mV, mA (APAX-5017)
Analog Input
V, mV, mA, Thermocouple (APAX-5018)
Voltage: >10 MW (APAX-5017), >1 MW (APAX-5018)
Channels
8
Input Impedance
Input Impedance
Input Type
>10 MW
Current: 120W (Current)
Pt-100, Pt-200, Pt-500, Pt-1000, Balco, Ni 518 RTD
(3-wire)
Voltage/Current Range 150 mV, 500 mV, 1 V, 5 V, 10 V, 20 mA,
0 ~ 20 mA, 4 ~ 20 mA (APAX-5017)
Temperature Range
Pt-100, Pt-200, Pt-500, Pt-1000:
-120 ~ 130° C, -200 ~ 850° C
Supports both IEC 60751 ITS90 (0.03851 W/W/° C)
and JIS C 1604 (0.03916 W/W/° C)
Balco 500: -30 ~ 120° C
50 mV, 100 mV, 500 mV, 1 V, 2.5 V, 20 mA,
0 ~ 20 mA, 4 ~ 20 mA (APAX-5018)
Temperature Range
(APAX-5018 only)
Type J (-210 ~ 1200° C), Type K (-270 ~ 1372° C),
Type T (-270 ~ 400° C), Type E (-270 ~ 1000° C),
Type R (0 ~ 1768° C), Type S (0 ~ 1768° C),
Type B (300 ~ 1820° C)
Ni 518: -80 ~ 100° C, 0 ~ 100° C
Yes
Configure Different
Range for Each Channel
Resolution
Yes
Configure Different
Range for Each Channel
Resolution
Sampling Rate
CMR @ 50/60 Hz
NMR @ 50/60 Hz
Noise Rejection
16-bit with accuracy 0.1% or better of Full Scale Range
(Voltage),
0.2% or better of Full Scale Range(Current)
16-bit
10 sample/second (total)
90 dB
60 dB
Note: Refer to manual for Thermocouple accuracy
Sampling Rate
Conversion Time
CMR @ 50/60 Hz
NMR @ 50/60 Hz
Noise Rejection
12 samples/second (total)
100 ms (per channel)
92 dB
Hardware Filter (50/60 Hz)
60 dB
Protection
Isolation between
Channels and Backplane
Hardware Filter (50/60 Hz)
2,500 VDC
Wire Burn-out Detection Yes (APAX-5081 only, for Thermocouple)
Protection
Isolation between
2,500 VDC
Environment
Channels and Backplane
Operating Temperature -10 ~ 60° C (when mounted vertically)
Storage Temperature -40 ~ 70° C
Relative Humidity
Supports Over Voltage Protection
Environment
5 ~ 95% (non-condensing)
Operating Temperature -10 ~ 60° C (when mounted vertically)
Storage Temperature
Relative Humidity
-40 ~ 70° C
5 ~ 95% (non-condensing)
Ordering Information
Ordering Information
APAX-5013
APAX-5001
APAX-5002
APAX-5343E
8-ch RTD Module
1-slot Backplane Module
2-slot Backplane Module
Power Supply for APAX Expansion Module
APAX-5017
APAX-5018
APAX-5001
APAX-5002
APAX-5343E
12-ch Analog Input Module
12-ch Thermocouple Input Module
1-slot Backplane Module
2-slot Backplane Module
Power Supply for APAX Expansion Module
Online Download
www.advantech.com/products