Click on Series name for product info on aimtec.com
Series AMEPR30C-AZ
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
AC-DC Constant Current or Constant
Voltage LED Driver
Input range 90-305VAC/47-440Hz
High efficiency up to 83%
Operating temperature -40 to 85°C
Dimmable via resistive / 0-10Vdc / PWM
5 Years Limited Warranty
Over temperature protection
Over current protection
Waterproof case rated IP68
Power Factor Correction
Short circuit protection
Models
Single output
Max
Output
Efficiency
Output
Input
Voltage
(VAC/Hz)
Input
Output
Power
Voltage
Range
(%)
Current
Model
Voltage Mode of Operation
(VDC)
③
115
230
277
(A)
①
③
VAC
VAC
VAC
(W)
(V)
Constant Current
83
83
83
83
83
83
82
82
80
80
83
83
83
83
83
83
82
82
80
80
83
83
83
83
83
83
82
82
80
80
AMEPR30C-5070AZ
AMEPR30C-4864AZ
AMEPR30C-36100AZ
AMEPR30C-24140AZ
AMEPR30C-12250AZ
35
30.7
36
36-50
36-48
24-36
12-24
5-12
0.7
0.64
1
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
②
Constant Voltage
Constant Current
②
Constant Voltage
Constant Current
②
Constant Voltage
Constant Current
33.6
30
1.4
2.5
②
Constant Voltage
Constant Current
②
Constant Voltage
①
Exceeding the maximum output power will permanently damage the converter.
.
②
In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models
can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when
ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMEPR30C-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
Typical
Maximum
430
Units
mA
mA
mA
A
Current (full load)
250
210
25
Inrush current <2ms (cold start)
Leakage current
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
40
55
0.25
3.5
A
A
mA
mA
0.96
0.90
0.85
1
Power factor
230 VAC
277 VAC
Recommended slow blow type
External fuse
Start-up time
A
ms
450
www.aimtec.com
F 052.1e R3.G
Tel: +1 514 620 2722
1 of 17
Toll free: + 1 888 9 AIMTEC
(924 6832)