Click on Series name for product info on aimtec.com
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
FEATURES:
AC-DC Constant current LED Driver
Input range 90-264VAC/47-440Hz
Active PFC with TRIAC dimmable
Operating temperature -20 to 80°C
Total Harmonic Distortion < 20%
5 Year Limited Warranty
Leading or Trailing Edge Triac
IP67 Case
High Efficiency up to 87%
SCP, Over Load Protection
②
Models
Single output
No Load
Output
Voltage
(V max.)
Max
Output
Voltage
Range
(V)
36-50
32-42
24-36
24-36
12-24
12-24
8-15
Efficiency
Output
Power
Output
Current (A)
Input Voltage
(VAC/Hz)
(%)
Model
115
230
①
VAC
VAC
(W)
②
AMEPR30D-5070AZ +Suffix
AMEPR30D-4270AZ+Suffix
AMEPR30D-3670AZ+Suffix
AMEPR30D-36100AZ+Suffix
AMEPR30D-24125AZ+Suffix
AMEPR30D-24140AZ+Suffix
AMEPR30D-15200AZ+Suffix
35
29.4
25.2
36
64
54
52
52
34
34
23
0.7
0.7
0.7
1
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
82
84
83
83
82
80
78
85
87
84
84
84
83
80
②
②
②
②
②
②
30
1.25
1.4
2
33.6
30
①
Exceeding the maximum output power will permanently damage the converter.
②
Model Nomenclature for Ordering:
Add Suffix “-U”
Add Suffix “-110”
Add Suffix “-220”
Universal AC input 90-264VAC, (no TRIAC dimming option)
AC input 90-135VAC, 115VAC typical value
AC input 180-264VAC, 230VAC typical value
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-
sale
AMEPR30D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone
to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause
early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms (cold start)
Leakage current
Conditions
115VAC
230VAC
Typical
15
30
0.25
500
350
Maximum
Units
A
mA
mA
115VAC
230VAC
AC current
115VAC
230VAC
Recommended slow blow
type
0.9
0.9
1
Power Factor
External fuse
A
Start up time
200
ms
Output Specifications
Parameters
Current accuracy
Line regulation
Conditions
Typical
Maximum
Units
%
%
±7
±10
±7
LL-HL
0-100% load
Load regulation
%
www.aimtec.com
F 052.1e R3.T
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only