Click on Series name for product info on aimtec.com
Series AMEL20-CJZ
20 Watt | AC-DC / DC-DC Converter
Picture Coming Soon
FEATURES:
•
I/O Isolation 4000VAC
•
•
•
•
Low no load consumption ≤0.3W
Continuous Short Circuit Protection
Up to 83% efficiency
• Operating Temp: -40°C to +70°C
• Over current, Over Voltage Protection
•
Input: 85-264VAC, 47-440Hz, or 100-370VDC
Low ripple and noise
Models
Single output
Maximum
capacitive
load
Max
Input
Voltage
(VDC)
Output
Voltage
(V)
Output
Current
max (A)
Input Voltage
Efficiency
Output
wattage
(W)
Model
(VAC/Hz)
(%)
(µF)
AMEL20-3.3SCJZ
AMEL20-5SCJZ
AMEL20-9SCJZ
AMEL20-12SCJZ
AMEL20-15SCJZ
AMEL20-24SCJZ
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
100-370
100-370
100-370
100-370
100-370
100-370
11.88
18
20
20
20
3.3
5
9
12
15
24
3.6
3.6
2.2
1.6
1.3
0.8
10,000
6600
4400
3000
2000
800
74
78
79
82
83
83
20
*Output power must not exceed the listed values.
Note: Add suffix “-ST” for optional screw terminal bottom plate or “-STD” for optional DIN Rail screw terminal bottom plate. (ex. AMEL20-3.3SCJZ-ST,
AMEL20-3.3SCJZ-STD).
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless
otherwise specified.
Input Specifications
Parameters
Conditions
115VAC
230VAC
115VAC
230VAC
Typical
0.37
0.24
12
36
3.15
Maximum
Units
A
A
A
A
A
Current
Inrush current <2ms (cold start)
External fuse
slow blow type
Output Specifications
Parameters
Conditions
3.3V output
Others
Typical
±3
Maximum
Units
Voltage accuracy
%
±2
Line regulation
Load regulation
Ripple & Noise
Full load
±0.5
±1
50
10
55
%
%
mV p-p
ms
0%-100% load
20MHz bandwidth
115VAC
120
Hold up time
230VAC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
Typical
Rated
4000
Units
VAC
MΩ
60 sec
>1000
General Specifications
Parameters
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Conditions
100% load
Typical
100
Class II
≥110
Maximum
Units
KHz
Auto recovery
% of Iout
Zener Diode Clamp
Continuous
Auto recovery
-40 to +70
Operating temperature
Maximum case temperature
See derating table
oC
oC
100
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only