5秒后页面跳转
AMEL20-24SCJZ PDF预览

AMEL20-24SCJZ

更新时间: 2024-11-26 00:58:59
品牌 Logo 应用领域
AIMTEC /
页数 文件大小 规格书
5页 622K
描述
AC-DC / DC-DC Converter

AMEL20-24SCJZ 数据手册

 浏览型号AMEL20-24SCJZ的Datasheet PDF文件第2页浏览型号AMEL20-24SCJZ的Datasheet PDF文件第3页浏览型号AMEL20-24SCJZ的Datasheet PDF文件第4页浏览型号AMEL20-24SCJZ的Datasheet PDF文件第5页 
Click on Series name for product info on aimtec.com  
Series AMEL20-CJZ  
20 Watt | AC-DC / DC-DC Converter  
Picture Coming Soon  
FEATURES:  
I/O Isolation 4000VAC  
Low no load consumption ≤0.3W  
Continuous Short Circuit Protection  
Up to 83% efficiency  
Operating Temp: -40°C to +70°C  
Over current, Over Voltage Protection  
Input: 85-264VAC, 47-440Hz, or 100-370VDC  
Low ripple and noise  
Models  
Single output  
Maximum  
capacitive  
load  
Max  
Input  
Voltage  
(VDC)  
Output  
Voltage  
(V)  
Output  
Current  
max (A)  
Input Voltage  
Efficiency  
Output  
wattage  
(W)  
Model  
(VAC/Hz)  
(%)  
(µF)  
AMEL20-3.3SCJZ  
AMEL20-5SCJZ  
AMEL20-9SCJZ  
AMEL20-12SCJZ  
AMEL20-15SCJZ  
AMEL20-24SCJZ  
85-264/47-440  
85-264/47-440  
85-264/47-440  
85-264/47-440  
85-264/47-440  
85-264/47-440  
100-370  
100-370  
100-370  
100-370  
100-370  
100-370  
11.88  
18  
20  
20  
20  
3.3  
5
9
12  
15  
24  
3.6  
3.6  
2.2  
1.6  
1.3  
0.8  
10,000  
6600  
4400  
3000  
2000  
800  
74  
78  
79  
82  
83  
83  
20  
*Output power must not exceed the listed values.  
Note: Add suffix “-ST” for optional screw terminal bottom plate or “-STD” for optional DIN Rail screw terminal bottom plate. (ex. AMEL20-3.3SCJZ-ST,  
AMEL20-3.3SCJZ-STD).  
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless  
otherwise specified.  
Input Specifications  
Parameters  
Conditions  
115VAC  
230VAC  
115VAC  
230VAC  
Typical  
0.37  
0.24  
12  
36  
3.15  
Maximum  
Units  
A
A
A
A
A
Current  
Inrush current <2ms (cold start)  
External fuse  
slow blow type  
Output Specifications  
Parameters  
Conditions  
3.3V output  
Others  
Typical  
±3  
Maximum  
Units  
Voltage accuracy  
%
±2  
Line regulation  
Load regulation  
Ripple & Noise  
Full load  
±0.5  
±1  
50  
10  
55  
%
%
mV p-p  
ms  
0%-100% load  
20MHz bandwidth  
115VAC  
120  
Hold up time  
230VAC  
ms  
Isolation Specifications  
Parameters  
Tested I/O voltage  
Isolation resistance  
Conditions  
Typical  
Rated  
4000  
Units  
VAC  
MΩ  
60 sec  
>1000  
General Specifications  
Parameters  
Switching frequency  
Protection class  
Over current protection  
Over voltage protection  
Short circuit protection  
Short circuit restart  
Conditions  
100% load  
Typical  
100  
Class II  
110  
Maximum  
Units  
KHz  
Auto recovery  
% of Iout  
Zener Diode Clamp  
Continuous  
Auto recovery  
-40 to +70  
Operating temperature  
Maximum case temperature  
See derating table  
oC  
oC  
100  
www.aimtec.com  
F 052e R8.D  
Tel: +1 514 620 2722  
1 of 5  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only  

与AMEL20-24SCJZ相关器件

型号 品牌 获取价格 描述 数据表
AMEL20-24SMAZ AIMTEC

获取价格

20 Watt | AC-DC Converter
AMEL20-24SMAZ-ST AIMTEC

获取价格

AC/DC Converter; Product Weight (grams): 70;
AMEL20-3.312DMAZ AIMTEC

获取价格

20 Watt | AC-DC Converter
AMEL20-3.312DMAZ-ST AIMTEC

获取价格

AC/DC Converter; Product Weight (grams): 70;
AMEL20-3.315DMAZ AIMTEC

获取价格

20 Watt | AC-DC Converter
AMEL20-3.315DMAZ-ST AIMTEC

获取价格

AC/DC Converter; Product Weight (grams): 70;
AMEL20-3.324DMAZ AIMTEC

获取价格

20 Watt | AC-DC Converter
AMEL20-3.324DMAZ-ST AIMTEC

获取价格

AC/DC Converter; Product Weight (grams): 70;
AMEL20-3.35DMAZ AIMTEC

获取价格

20 Watt | AC-DC Converter
AMEL20-3.35DMAZ-ST AIMTEC

获取价格

AC/DC Converter; Product Weight (grams): 70;