Click on Series name for product info on aimtec.com
Series AMEL10-CJZ
10 Watt | AC-DC / DC-DC Converter
FEATURES:
• I/O Isolation 4000VAC
•
•
•
•
Low Ripple Noise
Continuous Short Circuit Protection
Up to 83% efficiency
• Operating Temp: -40°C to +70°C
• Over current, Over Voltage Protection
• Input: 85-264VAC, 47-63Hz, or 100-370VDC
Meets IEC/UL/EN62368 & EN60335
Models
Single output
Maximum
capacitive
load
Input
Voltage
(VDC)
Output
Voltage
(V)
Output
Current max
(A)
Efficiency
@ 230VAC
(%)
Max Output
wattage
(W)
Input Voltage
Model
(VAC/Hz)
(µF)
AMEL10-3.3CSJZ
AMEL10-5CSJZ
AMEL10-9CSJZ
AMEL10-12CSJZ
AMEL10-15CSJZ
AMEL10-24CSJZ
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
100-370
100-370
100-370
100-370
100-370
100-370
6.6
10
10
10
10
10
3.3
5
9
12
15
24
2.00
2.00
1.10
0.90
0.70
0.45
26,400
9,440
3,600
2,000
1,170
370
71
76
80
81
81
83
*Output power must not exceed the listed values.
Note:
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless
otherwise specified.
Input Specifications
Parameters
Conditions
115VAC
230VAC
115VAC
230VAC
Typical
0.23
0.15
Maximum
Units
A
A
A
A
A
Current
15
30
Inrush current <2ms (cold start)
External fuse
slow blow type
2
Output Specifications
Parameters
Conditions
3.3V output
Others
Typical
±3
Maximum
Units
Voltage accuracy
%
±2
Line regulation
Load regulation
Ripple & Noise
Hold up time
Full load
±0.5
±1
50
%
%
mV p-p
ms
10-100% load
20MHz bandwidth
230VAC
100
80
Isolation Specifications
Parameters
Conditions
Typical
>1000
Rated
4000
Units
VAC
MΩ
Tested I/O voltage
Isolation resistance
60 sec
General Specifications
Parameters
Switching frequency
Protection class
Conditions
100% load
Typical
100
Class II
110 - 300
Maximum
Units
KHz
Over current protection
Auto recovery
3.3V/5V Vout
9V Vout
12V/15V Vout
24V Vout
% of Iout
≤7.5
≤15
≤20
≤30
Over voltage protection
VDC
Short circuit protection
Short circuit restart
Operating temperature
Continuous
Auto recovery
-40 to +70
See derating table
oC
www.aimtec.com
F 052e R8.B
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only