Click on Series name for product info on aimtec.com
Series AMEL10-MJZ
10 Watt | AC-DC / DC-DC Converter
Picture coming soon
FEATURES:
• I/O Isolation 4000VAC
•
•
•
Low no load consumption ≤0.5W
Continuous Short Circuit Protection
Up to 83% efficiency
• Operating Temp: -25°C to +70°C
• Over current, Over Voltage
•
Input: 85-264VAC, 47-440Hz, or 100-370VDC
Models
Single output
Maximum
capacitive
load
Input
Voltage
(VDC)
Output
Voltage
(V)
Output
Current max
(A)
Max Output
wattage
(W)
Input Voltage
Efficiency
Model
(VAC/Hz)
(%)
(µF)
AMEL10-3.3SMJZ
AMEL10-5SMJZ
AMEL10-9SMJZ
AMEL10-12SMJZ
AMEL10-15SMJZ
AMEL10-24SMJZ
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
100-370
100-370
100-370
100-370
100-370
100-370
6.6
10
10
10
10
10
3.3
5
9
12
15
24
2.00
2.00
1.10
0.90
0.70
0.45
15,000
12,000
6,000
2,000
1,500
71
76
80
81
82
83
500
*Output power must not exceed the listed values.
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless
otherwise specified.
Input Specifications
Parameters
Conditions
115VAC
230VAC
Typical
0.23
0.15
Maximum
Units
A
A
Current
115VAC
230VAC
10
20
A
A
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
0.25
mA
A
W
slow blow type
No Load
2
≤0.5
Output Specifications
Parameters
Conditions
3.3V output
Others
Typical
±3
Maximum
Units
Voltage accuracy
%
±2
Line regulation
Load regulation
Ripple & Noise
Hold up time
Full load
±0.5
±1
50
%
%
mV p-p
ms
10-100% load
20MHz bandwidth
230VAC
100
80
Isolation Specifications
Parameters
Tested I/O voltage
Conditions
Typical
Rated
4000
Units
VAC
MΩ
60 sec
Isolation resistance
>1000
General Specifications
Parameters
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Conditions
100% load
Typical
Maximum
Units
KHz
65
Class II
110 - 200
Auto recovery
% of Iout
Zener Diode Clamp
Continuous
Auto recovery
-25 to +70
Operating temperature
See derating table
oC
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only