Click on Series name for product info on aimtec.com
Series AME2-AZ
2Watt | AC-DC Converter
FEATURES:
• I/O Isolation 3000VAC
• RoHS compliant
• Energy Star compliant
• Operating Temp: -40°C to +70°C
• Input: 90-305VAC, 47-440Hz, or 130-430 VDC
• Optional 90-528VAC, 47-440Hz, or 130-745 VDC
• Over load, Short Circuit Protection
• Ultra small package
Models
Single output
Maximum
capacitive
Efficiency
(%)
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
Output
Voltage
(V)
Output
Current max
(mA)
Model
Load
(µF)
115
230
277
480
(ºC)
VAC
VAC
VAC
VAC
AME2-3.3SAZ
AME2-5SAZ
AME2-12SAZ
AME2-15SAZ
AME2-24SAZ
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
-40 to +70
-40 to +70
-40 to +70
-40 to +70
-40 to +70
3.3
5
12
15
24
600
400
166
133
83
2200
1100
680
560
470
64
67
75
78
81
63
66
72
74
81
61
63
69
71
79
AME2-3.3SBAZ
AME2-5SBAZ
AME2-12SBAZ
AME2-15SBAZ
AME2-24SBAZ
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
130-745
130-745
-40 to +70
-40 to +70
-40 to +70
-40 to +70
-40 to +70
3.3
5
12
15
24
600
400
166
133
83
2200
1100
680
560
470
57
63
68
68
67
57
63
68
67
67
56
62
66
66
65
50
56
53
57
58
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
277 VAC
480VAC
Typical
Maximum
Units
mA
mA
mA
mA
A
A
A
A
40
20
20
15
10
15
20
30
Current (full load)
115 VAC
230 VAC
277 VAC
480 VAC
Inrush current <2ms (cold start)
Leakage current
External fuse
0.15
mA
A
Recommended slow blow type
1
Input Dissipation (No Load)
W
≦0.3
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient Recovery Time
Transient Response Deviation
Minimum load
Conditions
Full load (typical)*
LL-HL, Full Load
Typical
±5
±1.5
±5
Maximum
Units
%
%
%
µs
0-100% load (typical)*
200
±2
0
25% load step
% of Vout
%
3.3/5 VAC With 560µF E/C
12/15 VAC With 220µF E/C
24 VAC With 220µF E/C
200
400
500
mV p-p
mV p-p
mV p-p
Ripple & Noise
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1µF and 115/230/277/480 VAC( Typical input ) with Full Load
Isolation Specifications
Parameters
Conditions
Typical
Rated
3000
Units
VAC
MΩ
Tested I/O voltage
60 sec
Isolation Resistance
>1000
www.aimtec.com
F 052e R8.I
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only