AME15-277VZ
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Class Ⅱ
≥ 150
Safety class
Over Current protection
Auto recovery
3.3V/5V Vout
9V Vout
300
7.5
15
% of Iout
12V/15V Vout
24V Vout
20
30
VDC
Over voltage protection
48V Vout
60
Hiccup, Continuous, Auto recovery
-40 to +85
Short circuit protection
Operating temperature
Storage temperature
See derating graph
oC
oC
-40 to +105
Wave soldering
Hand soldering
48V Vout
260 ± 5 oC; time:5 - 10s
Lead temperature
360 ± 10 oC; time:3 - 5s
0.55
0.5
W
W
Power consumption
Others
-40 oC ~ -25 oC
55 oC ~ 70 oC
70 oC ~ 85 oC
85VAC ~ 100VAC
277VAC ~ 305VAC
4
3.34
2.67
1.67
0.72
% / oC
Power derating
% / VAC
% / oC
±0.02
Free air convection
Temperature coefficient
Cooling
Non-condensing
95
% RH
Humidity
Heat resistant black Plastic (flammability to UL 94V-0)
Case material
PCB mountable models
90
With optional -ST mounting plate:
With optional -STD mounting plate:
PCB mountable models
With optional -ST mounting plate:
With optional -STD mounting plate:
140
180
g
Weight
2.44 x 1.77 x 0.89 inches (62.0 x 45.0 x 22.5mm)
3.78 x 2.13 x 1.22 inches (96.1 x 54.0 x 31.0mm)
3.78 x 2.13 x 1.40 inches (96.1 x 54.0 x 35.6mm)
Dimensions (L x W x H)
MTBF
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated
output load unless otherwise specified.
Safety Specifications
Parameters
Information technology Equipment
EMC - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Design to meet IEC/EN/UL 62368
CISPR32 / EN55032, class B
IEC 61000-4-2 Contact ±6KV / Air ±8KV, Criteria B
IEC 61000-4-3 10V/m, Criteria A
IEC 61000-4-4 ±2KV, Criteria B
Electrical Fast Transient/Burst Immunity
Surge Immunity
Standards
IEC 61000-4-4 ±4KV, with EMC recommended circuit, Criteria B
IEC 61000-4-5 L-L ±1KV/L-G ±2KV, Criteria B
IEC 61000-4-5 L-L ±2KV/L-G ±4KV, with EMC recommended circuit, Criteria B
IEC 61000-4-6 10Vr.m.s, Criteria A
RF, Conducted Disturbance Immunity
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11 0%, 70%, Criteria B
F 052e R4
www.Aimtec.com