5秒后页面跳转
ALTG-311-B PDF预览

ALTG-311-B

更新时间: 2024-11-05 01:33:23
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
4页 126K
描述
Limit Alarms (rotary switch adj.) AL-UNIT

ALTG-311-B 数据手册

 浏览型号ALTG-311-B的Datasheet PDF文件第2页浏览型号ALTG-311-B的Datasheet PDF文件第3页浏览型号ALTG-311-B的Datasheet PDF文件第4页 
MODEL: ALTG  
U: Specify voltage (See INPUT SPECIFICATIONS)  
Limit Alarms (rotary switch adj.) AL-UNIT  
(0 % input must be 0 V.)  
TACHOGENERATOR ALARM  
Functions & Features  
[2] SETPOINT 1 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
• Providing SPDT relay outputs at preset AC voltage levels  
from a tachogenerator  
• Dual (Hi/Lo) trip  
• Energized or de-energized coil at a tripped condition  
selectable  
• Rotary switch setpoint adjustments  
• Enclosed relays  
[3] SETPOINT 2 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
• Relays can be powered 110 V DC  
• High-density mounting  
Typical Applications  
• Annunciator  
[4] POWER INPUT  
AC Power  
• Various alarm applications  
50  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
(1.97)  
80  
(3.15)  
132  
(5.20)  
DC Power  
mm (inch)  
S: 12 V DC  
R: 24 V DC  
MODEL: ALTG-[1][2][3]-[4][5]  
V: 48 V DC  
P: 110 V DC  
ORDERING INFORMATION  
• Code number: ALTG-[1][2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. ALTG-111-B/Q)  
[5] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
• Special input range (For code U)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
[1] INPUT  
/C02: Polyurethane coating  
Voltage  
/C03: Rubber coating  
1: 0 – 35 V AC (Input resistance 100 kΩ min.)  
2: 0 – 50 mV AC (Input resistance 100 kΩ min.)  
3: 0 – 60 mV AC (Input resistance 100 kΩ min.)  
4: 0 – 100 mV AC (Input resistance 100 kΩ min.)  
5: 0 – 1 V AC (Input resistance 100 kΩ min.)  
6: 0 – 10 V AC (Input resistance 100 kΩ min.)  
7: 0 – 100 V AC (Input resistance 100 kΩ min.)  
8: 0 – 110 V AC (Input resistance 100 kΩ min.)  
9: 0 – 150 V AC (Input resistance 100 kΩ min.)  
A: 0 – 200 V AC (Input resistance 100 kΩ min.)  
B: 0 – 250 V AC (Input resistance 100 kΩ min.)  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output 1 to output 2 to power  
Setpoint adjustments: 10-position rotary switches (front); 0  
ALTG SPECIFICATIONS  
ES-2739 Rev.8 Page 1/4  
http://www.m-system.co.jp/  

与ALTG-311-B相关器件

型号 品牌 获取价格 描述 数据表
ALTG-311-B/Q MSYSTEM

获取价格

Limit Alarms (rotary switch adj.) AL-UNIT
ALTG-311-C MSYSTEM

获取价格

Limit Alarms (rotary switch adj.) AL-UNIT
ALTG-311-C/Q MSYSTEM

获取价格

Limit Alarms (rotary switch adj.) AL-UNIT
ALTG-311-D MSYSTEM

获取价格

Limit Alarms (rotary switch adj.) AL-UNIT
ALTG-311-D/Q MSYSTEM

获取价格

Limit Alarms (rotary switch adj.) AL-UNIT
ALTG-311-F MSYSTEM

获取价格

Limit Alarms (rotary switch adj.) AL-UNIT
ALTG-311-F/Q MSYSTEM

获取价格

Limit Alarms (rotary switch adj.) AL-UNIT
ALTG-311-G MSYSTEM

获取价格

Limit Alarms (rotary switch adj.) AL-UNIT
ALTG-311-G/Q MSYSTEM

获取价格

Limit Alarms (rotary switch adj.) AL-UNIT
ALTG-311-J MSYSTEM

获取价格

Limit Alarms (rotary switch adj.) AL-UNIT