IPN = 2..200A
AC Current transducer AKR-B420L
ASplitCoretransducerfortheelectronicmeasurementACwaveforms
current, with galvanic isolation between the primary (High power) and
the secondary circuits (Electronic circuit). Jumper selectable ranges
and True RMS 4-20mA current output.
Electrical data
Features
Analogue Output Signal1)
IOUT (mA)
Type
RoHS
· VFD and SCR waveforms current
measurement
Primary Nominal Current
IPN (A.t.RMS)
Date Code
· True RMS responding
· Split core box
2,5
4-20
AKR 5 B420L JUNE 2006
· Current output
10,20,50
4-20
4-20
AKR 50 B420L planned
AKR 200 B420L planned
· Loop powered transducers
· Panel mounting
100,150,200
· Jumper selectable ranges
Vc
Supply voltage (Loop powered)
24
V DC
RL
Vb
Vd
f
Load resistance
see power supply diagram
150
Rated voltage (CAT III, PD2)
V AC
kV AC
Hz
Advantages
RMS Isolation voltage test, 50 Hz, 1mn
Frequency bandwith
3
10-400
· Large aperture
· High isolation between primary and
secondary circuits
Accuracy - Dynamic performance data
· Easy to mount
X
tr
Accuracy@ IPN, TA=25°C
± 1
%
Response time @ 90% of IPN
< 600
mS
Applications
General data
· VFD Controlled Loads: VFD output
indicates how the motor and
attached load are operating.
· SCR Controlled Loads:
TA
TS
m
Ambient operating temperature (0-95% RH)
Ambient storage temperature
- 20 ..+ 50
- 20 ..+ 85
°C
°C
g
Mass
Safety
EMC
120
Acurate measurement of phase
angle fired or burst fired (time
proportioned) SCRs.
IEC 61010-1
EN 61326
· Switching Power Supplies and
Electronic Ballasts: True RMS sensing
is the most accurate way to
measure power supply or ballast
input power.
Note: 1) For 4-20mA output model, no saturation output up to 23 mA.
Selecting the transducer
VFD (Variable Frequency Drive) and SCR (Semi Conductor Rectifier) output
waveforms are rough approximations of a sine wave. There are numerous spikes
and dips in each cycle. AKR transducers use a mathematical algorithm called
“True RMS,” which integrates the actual waveform over time. True RMS is the only
way to accurately measure distorted AC waveforms. Select AKR transducers for
nonlinear loads or in “noisy” power environments.
Options on request
· DIN mounting
060816/5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 1/2
LEM