|
8
A-Series Circuit Breaker - Handle WORLD – Ordering Scheme
A A 3 B 0 14 450 1 A 1 P
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
9
1 SERIES
A
8 TERMINAL
10
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
B
Screw M5 with upturned lugs
Screw M4 with upturned lugs
Screw M4 (Bus Type)
Screw M5 with upturned lugs
& 30° bend
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
C
E
F
11
11
11
1
2 ACTUATOR
A
B
S
T
Handle, one per pole
Handle, one per multipole unit
Mid-Trip Handle, one per pole
G
H
R
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
Screw M4 with upturned lugs
& 30° bend
Screw M4 (Bus Type)
& 30° bend
11
11
Mid-Trip Handle, one per pole & Alarm Switch
7
8
9
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
Screw 10-32 (Bus Type)
& 30° bend
T
3 POLES
1
2
One
Two
3
4
Three
Four
5
6
Five
Six
4 CIRCUIT
2
3
3
3,4
A
B
C
Switch Only (No Coil)
D
E
H
Shunt Trip (Current)
Shunt Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
9 ACTUATOR COLOR & LEGEND
Series Trip (Current)
Series Trip (Voltage)
Actuator Color
I-O
A
C
F
H
K
M
P
R
T
Dual
Legend Color
Black
White
1
2
3
4
5
6
7
8
9
Black
White
Red
White
Green
White
5
Blue
White
5 AUXILIARY / ALARM SWITCH
Yellow
Black
0
2
4
without Aux Switch
Gray
Black
S.P.D.T., 0.110 Q.C. Term.
Orange
Black
S.P.D.T., 0.110 Q.C. Term. (Gold Contacts)
Black (short handle)15
White
10 MOUNTING / BARRIERS
MOUNTING STYLE
6 FREQUENCY & DELAY
BARRIERS
03
10
11
12
14
16
20
21
22
24
26
DC 50/60Hz, Switch Only
DC Instantaneous
DC Ultra Short
DC Short
30
31
32
34
36
42
44
46
52
54
56
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short,Hi-Inrush
DC, Medium, Hi-Inrush
DC, Long, Hi-Inrush
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
6-32 x 0.195 inches
ISO M3 x 5mm
no
A
2
yes
no
DC Medium
B
ISO M3 x 5mm (multipole only)
yes
7
7
7
7
7
7
DC Long
Front panel Snap-In, 0.75” wide bezel
without Handleguard
50/60Hz Instantaneous
50/60Hz Ultra Short
50/60Hz Short
5
6
no
yes
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
without Handleguard, 1-pole 0.96” wide;
multipole units have .105” bezel overhang on all sides
without Handleguard, 1-pole 0.96” wide;
(multipole only) .105” bezel overhang on all sides
50/60Hz Medium
50/60Hz Long
7
8
no
yes
7 CURRENT RATING (AMPERES)
CODE AMPERES
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
11 AGENCY APPROVAL
P
TUV Certified, UL Recognized & CSA Accepted
Q
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit
codes B, C, D, E, and H.
8
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a
protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630.
For 35 - 50 amps, select Current Code 650.
635 35.000
8
640 40.000
2
8
645 45.000
8
650 50.000
6
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
3
4
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require
30VA minimum power to trip and are rated for intermittent duty only.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10, 20 & 30.
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
5
6
J06
6 AC
7
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA
Accepted & TUV Certified to 50 amps.
8
9
Available up to two poles with AC or DC delays.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G and H.
10 Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20 amps.
11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers.
These breakers are only TUV Certified when the washers are used.
12 Single pole only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com