SN54AHC05, SN74AHC05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCLS357H – MAY 1997 – REVISED JULY 2003
SN54AHC05 . . . J OR W PACKAGE
SN74AHC05 . . . D, DB, DGV, N, OR PW PACKAGE
(TOP VIEW)
Operating Range 2-V to 5.5-V V
CC
Latch-Up Performance Exceeds 250 mA Per
JESD 17
ESD Protection Exceeds JESD 22
– 2000-V Human-Body Model (A114-A)
– 200-V Machine Model (A115-A)
1A
1Y
V
CC
13 6A
1
2
3
4
5
6
7
14
12
11
10
9
2A
6Y
5A
5Y
4A
4Y
– 1000-V Charged-Device Model (C101)
2Y
3A
description/ordering information
3Y
8
GND
The ’AHC05 devices contain six independent
inverters. These devices perform the Boolean
function Y = A.
SN54AHC05 . . . FK PACKAGE
(TOP VIEW)
The open-drain outputs require pullup resistors to
perform correctly. They can be connected to other
open-drain outputs to implement active-low
wired-OR or active-high wired-AND functions.
3
2
1 20 19
18
6Y
NC
5A
2A
NC
2Y
4
5
6
7
8
17
16
15 NC
14
9 10 11 12 13
NC
3A
5Y
NC – No internal connection
ORDERING INFORMATION
ORDERABLE
PART NUMBER
TOP-SIDE
MARKING
†
PACKAGE
T
A
PDIP – N
SOIC – D
Tube
SN74AHC05N
SN74AHC05N
Tube
SN74AHC05D
AHC05
Tape and reel
Tape and reel
Tube
SN74AHC05DR
SN74AHC05DBR
SN74AHC05PW
SN74AHC05PWR
SN74AHC05DGVR
SNJ54AHC05J
–40°C to 85°C
SSOP – DB
HA05
HA05
HA05
TSSOP – PW
Tape and reel
Tape and reel
Tube
TVSOP – DGV
CDIP – J
SNJ54AHC05J
SNJ54AHC05W
SNJ54AHC05FK
–55°C to 125°C
CFP – W
Tube
SNJ54AHC05W
SNJ54AHC05FK
LCCC – FK
Tube
†
Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines
are available at www.ti.com/sc/package.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright 2003, Texas Instruments Incorporated
UNLESS OTHERWISE NOTED this document contains PRODUCTION
DATA information current as of publication date. Products conform to
specifications per the terms of Texas Instruments standard warranty.
Production processing does not necessarily include testing of all
parameters.
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265