36-100Watts
AEBSeries
xppower.com
•
•
•
•
•
•
•
CEC2008 & EISA2007 Compliant
Low Profile
Single Outputs from 5 V to 48 V
High Power Density
Universal Input
China Compulsory Certification (CCC) Qualified
3 Year Warranty
Specification
Input
G eneral
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• AEB36: 1.00 A max
AEB45: 1.20 A max
AEB70: 1.50 A max
AEB100: 1.85 A max
• AEB36: 60 A max at 240 VAC
AEB45: 70 A max at 240 VAC
AEB70: 80 A max at 240 VAC
AEB100: 120 A max at 240 VAC
Efficiency
Energy Efficiency
• See tables
• AEB70: Level V
All other models: Level IV
Isolation
• AEB36: 3000 VAC Input to Output
AEB45/70/100: 3000 VAC Input to Output,
1500 VAC Input to Ground. Negative
output is connected to ground. For
optional 500 VAC output to ground
isolation add suffix ‘-F’ to model number
• AEB36: 60 kHz typical, AEB45: 100 kHz
typical, AEB70: 65 kHz typical,
AEB100: 80 kHz typical PFC converter
45 kHz typical main converter
• AEB36: 5.34 W/in , AEB45: 3.81 W/in ,
AEB70: 4.92 W/in , AEB100: 4.45 W/in
• AEB36: >360 kHrs, AEB45: >300 kHrs,
AEB70: >200 kHrs, AEB100: >150 kHrs
to MIL-HDBK-217F at 25 °C, GB
Inrush Current
Power Factor
Earth Leakage Current • <3.5 mA (AEB45/70/100)
Input Protection
Switching Frequency
• EN61000-3-2, class A
• Fitted with an internal fuse
AEB36 T1A/250 VAC,
AEB45/70/100 T2A/250 VAC
3
3
Power Density
MTBF
3
3
No Load Input Power • <0.5 W
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
• See tables
2%, set at 60% load
• No minimum load required
• 3 s max
• 20 ms
• AEB36/45/70: 8 ms at 115 VAC
AEB100: 20 ms at 115 VAC
Environmental
•
Operating Temperature • AEB36/45/70: 0 ˚C to +60 °C derate
linearly from 100% load at +40 °C to 60%,
load at +60 °C, AEB100: 0 °C to +60 °C
derate linearly from 100% load at +40 °C to
50% load at +60 °C
Storage Temperature
Operating Humidity
• -20 °C to +85 °C
• 93% RH, non-condensing
Drift
•
•
0.05%
1%
Line Regulation
Load Regulation
Ripple & Noise
EMC&Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
• See tables
• 1% pk-pk max, 20 MHz bandwidth,
(see note 2)
• 5% max deviation, recovery to within 1%
in 500 µs for a 25% load change
• EN55022, Level B conducted & radiated
• EN61000-3-2 Class A
• EN61000-3-3
• EN61000-4-2 Level 2 (contact) Perf Criteria A
EN61000-4-2 Level 3 (air) Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria B
• EN61000-4-6, Level 2 Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
Transient Response
Overvoltage Protection • Typical 125% max, latching
Overload Protection • Trip & restart mode (hiccup mode)
Short Circuit Protection • Continuous
Temperature
Coefficient
Radiated Immunity
EFT/Burst
Surge
•
0.04%/°C
Conducted Immunity
Magnetic Field
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
Safety Approvals
• EN60950-1:2006+A11, UL/cUL60950-1,
China Compulsory Certification (CCC)
qualified (AEB36/70 only)