Data Sheet
ADuM7704
PACKAGE CHARACTERISTICS
Table 3.
Parameter1
Symbol
RI-O
CI-O
Min
Typ
1012
1
Max
Unit
Ω
pF
Test Conditions/Comments
Frequency = 1 MHz
Resistance (Input to Output)
Capacitance (Input to Output)
1 The device is considered a 2-terminal device. For the 16-lead SOIC_W, Pin 1 to Pin 8 are shorted together and Pin 9 to Pin 16 are shorted together. For the 8-lead
SOIC_IC, Pin 1 to Pin 4 are shorted together and Pin 5 to Pin 8 are shorted together.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 4.
Parameter
Symbol Value
Unit
Test Conditions/Comments
Input to Output Momentary Withstand Voltage
Minimum External Air Gap (Clearance)1, 2
16-Lead SOIC_W
VISO
5700 min
V rms 1 minute duration
L(I01)
L(I01)
7.8 min
8.3 min
mm
mm
Measured from input terminals to output
terminals, shortest distance through air
Measured from input terminals to output
terminals, shortest distance through air
8-Lead SOIC_IC
Minimum External Tracking (Creepage)1
16-Lead SOIC_W
L(I02)
L(I02)
7.8 min
8.3 min
mm
mm
Measured from input terminals to output
terminals, shortest distance path along body
Measured from input terminals to output
terminals, shortest distance path along body
8-Lead SOIC_IC
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
0.041 min mm
Distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table I)
CTI
>600
I
V
1 In accordance with IEC 60950-1 guidelines for the measurement of creepage and clearance distances for a pollution degree of 2 and altitudes ≤ 2000 m.
2 Consideration must be given to pad layout to ensure the minimum required distance for clearance is maintained.
REGULATORY INFORMATION
Table 5.
UL
CSA
VDE
Recognized under 1577 Component
Recognition Program1
Approved under CSA Component Acceptance
Notice 5A
Certified according to DIN V VDE V 0884-102,
reinforced insulation, VIORM = 1270 VPEAK
,
VIOSM = 8000 VPEAK
5700 V rms Isolation Voltage Single
Protection
Basic insulation per CSA 60950-1-07 and
IEC 60950-1, ADuM7704: 780 V rms (1102 VPEAK),
ADuM7704-8: 830 V rms (1173 VPEAK) maximum
working voltage3
Reinforced insulation per CSA 60950-1-07 and
IEC 60950-1, ADuM7704: 390 V rms (551 VPEAK),
ADuM7704-8: 415 V rms (586 VPEAK) maximum
working voltage3
Certified according to DIN V VDE V 0884-11,
reinforced insulation, VIORM = 1060 VPEAK
VIOSM = 8000 VPEAK (pending)
,
Reinforced insulation per IEC 60601-1, 261 V rms
(369 VPEAK) maximum working voltage
1 In accordance with UL 1577, each ADuM7704 is proof tested by applying an insulation test voltage ≥ 6840 V rms for 1 sec (current leakage detection limit = 15 µA).
2 In accordance with DIN V VDE V 0884-10, each ADuM7704 is proof tested by applying an insulation test voltage ≥ 2344 VPEAK for 1 sec (partial discharge detection limit = 5 pC).
3 Rating is calculated for a pollution degree of 2 and a Material Group III. The ADuM7704 package material is rated by CSA to a comparative tracking index (CTI) of >600 V
and, therefore, Material Group I.
Rev. 0 | Page 5 of 22