Data Sheet
ADuM4120/ADuM4120-1
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 8. ADuM4120/ADuM4120-1 Maximum Continuous
Working Voltage1
Table 7.
Parameter
Rating
Parameter
Value
Constraint
Supply Voltages
VDD1 − GND1
VDD2 − GND2
Input Voltages
VIN1 − GND1
Output Voltages
VOUT − GND2
Common-Mode Transients (|CM|)2
Storage Temperature Range (TST)
Ambient Operating Temperature
Range (TA)
60 Hz AC Voltage
600 V rms
20-year lifetime at 0.1%
failure rate, zero average
voltage
−0.3 V to +7 V
−0.3 V to +40 V
DC Voltage
1092 V peak Limited by the creepage of
the package, Pollution Degree
2, Material Group II2, 3
−0.3 V to +7 V
1 See the Insulation Lifetime section for details.
−0.3 V to VDD2 + 0.3 V
−200 kV/μs to +200 kV/μs
−55°C to +150°C
2 Other pollution degree and material group requirements yield a different limit.
3 Some system level standards allow components to use the printed wiring
board (PWB) creepage values. The supported dc voltage may be higher for
those standards.
−40°C to +125°C
Table 9. Truth Table ADuM4120/ADuM4120-1 (Positive Logic)
VIN Input1 VDD1 State
1 Rating assumes VDD1 is above 2.5 V. VIN is rated up to 6.5 V when VDD1 is
unpowered.
VDD2 State
VOUT Output
Low
High
X
Powered
Powered
Unpowered2
Powered
Low
2 |CM| refers to common-mode transients across the insulation barrier.
Common-mode transients exceeding the absolute maximum rating can
cause latch-up or permanent damage.
Powered
High
Powered
Unpowered2
Low
High-Z
X
Powered
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
1 X means don’t care
2 Output returns within 20 μs of being powered.
ESD CAUTION
Rev. 0 | Page 7 of 17