155W Single Output with 5V, 3A DC-DC Converter
ADS-155 series
Features :
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC 67KHz, PWM 134KHz
2 years warranty
SPECIFICATION
MODEL
ADS-15512
ADS-15524
ADS-15548
OUTPUT NUMBER
CH1
CH2
5V
CH1
CH2
5V
CH1
CH2
5V
DC VOLTAGE
12V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
11.5A
0 ~ 12.5A
153W
3A
5.8A
3A
2.9A
3A
0 ~ 3A
0 ~ 6.5A
154.2W
150mVp-p
CH1:21.6 ~ 26.4V
1.0%
0 ~ 3A
0 ~ 3.2A
154.2W
240mVp-p
CH1:43.2 ~ 52.8V
1.0%
0 ~ 3A
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
100mVp-p
100mVp-p
100mVp-p
OUTPUT
CH1:10.8 ~ 13.2V
3.0%
0.5%
2.0%
3.0%
0.5%
2.0%
5.0%
0.5%
1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
0.5%
0.5%
1.0%
0.5%
1.0%
1000ms, 90ms/230VAC
2000ms, 90ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
24ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
PF>0.92
20ms/115VAC at full load
124 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
77%
82%
82%
INPUT
2.5A/115VAC
1.5A/230VAC
COLD START 20A/115VAC
<1mA / 240VAC
40A/230VAC
LEAKAGE CURRENT
OVERLOAD
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is reoved
CH1:13.8 ~ 16.2V CH1:27.6 ~ 32.4V CH1:55.2 ~ 64.8V
PROTECTION
ENVIRONMENT
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
202.3K hrs min. MIL-HDBK-217F (25
199*110*50mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
1Kg; 16pcs/16Kg/0.95CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:ADS-155-SPEC 2010-10-18