AD8233  
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS  
BALL A1  
AD8233  
INDICATOR  
1
2
3
4
5
GND  
+V  
REFIN HPSENSE HPDRIVE  
S
A
SDN  
AC/DC  
FR  
IAOUT  
+IN  
B
C
D
LOD RLD SDN REFOUT RLDFB  
–IN  
OUT  
OPAMP– OPAMP+  
SW  
RLD  
TOP VIEW  
(BALL SIDE DOWN)  
Not to Scale  
Figure 2. Pin Configuration  
Table 5. Pin Function Descriptions  
Pin No. Mnemonic Description  
A1  
A2  
A3  
A4  
GND  
+VS  
REFIN  
HPSENSE  
Power Supply Ground.  
Power Supply Terminal.  
Reference Buffer Input. Use REFIN, a high impedance input terminal, to set the level of the reference buffer.  
High-Pass Sense Input for Instrumentation Amplifier. Connect HPSENSE to the junction of R and C that sets the  
corner frequency of the dc blocking circuit.  
A5  
HPDRIVE  
High-Pass Driver Output. Connect HPDRIVE to the capacitor in the first high-pass filter. The AD8233 drives this pin  
to keep HPSENSE at the same level as the reference voltage.  
B1  
B2  
SDN  
Shutdown Control Input. Drive SDN low to enter the low power shutdown mode.  
AC/DC  
Leads Off Mode Control Input. Drive the AC/DC pin low for dc leads off mode. Drive the AC/DC pin high for ac  
leads off mode.  
B3  
B4  
B5  
C1  
C2  
C3  
FR  
IAOUT  
+IN  
LOD  
RLD SDN  
REFOUT  
Fast Restore Control Input. Drive FR high to enable fast recovery mode; otherwise, drive it low.  
Instrumentation Amplifier Output Terminal.  
Instrumentation Amplifier, Positive Input. +IN is typically connected to the left arm (LA) electrode.  
Leads Off Detection (LOD) Comparator Output.  
Right Leg Drive Shutdown Control Input. Drive RLD SDN low to power down the RLD amplifier.  
Reference Buffer Output. The instrumentation amplifier output is referenced to this potential. Use REFOUT as a  
virtual ground for any point in the circuit that requires a signal reference.  
C4  
C5  
D1  
RLDFB  
−IN  
OUT  
Right Leg Drive Feedback Input. RLDFB is the feedback terminal for the right leg drive circuit.  
Instrumentation Amplifier, Negative Input. −IN is typically connected to the right arm (RA) electrode.  
Operational Amplifier Output. The fully conditioned heart rate signal is present at this output. OUT can be  
connected to the input of an ADC.  
D2  
D3  
D4  
D5  
OPAMP−  
OPAMP+  
SW  
Operational Amplifier Inverting Input.  
Operational Amplifier Noninverting Input.  
Fast Restore Switch Terminal. Connect this terminal to the output of the second high-pass filter.  
Right Leg Drive Output. Connect the driven electrode (typically, right leg) to the RLD pin.  
RLD  
Rev. 0 | Page 7 of 29  
 

与AD8233相关器件

型号 品牌 描述 获取价格 数据表
AD8233ACBZ-R7 ADI 50 µA, 2 mm x 1.7 mm WLCSP, Low Noise, Heart Rate Monitor for Wearable Products

获取价格

AD8233CB-EBZ ADI Fitness and activity heart rate monitors

获取价格

AD8235 ADI 40 μA Micropower Instrumentation Amplifier in

获取价格

AD8235ACBZ-P7 ADI 40 μA Micropower Instrumentation Amplifier in

获取价格

AD8236 ADI Wide Supply Range, Rail-to-Rail

获取价格

AD8236ARMZ ROCHESTER OP-AMP, 3500 uV OFFSET-MAX, PDSO8, ROHS COMPLIANT, MO-187AA, MSOP-8

获取价格