Low Power, 16/24-Bit Sigma-Delta ADC with
Low-Noise In-Amp and Embedded Reference
Preliminary Technical Data
AD7792/AD7793
REFIN(+)/AIN3(+)
GND
AV
DD
REFIN(-)/AIN3(-)
FEATURES
Resolution:
V
BIAS
AD7792: 16-Bit
AD7793: 24-Bit
V
DD
BANDGAP
REFERENCE
GND
SERIAL
INTERFACE
AND
DOUT/RDY
DIN
AIN1(+)
Low Noise Programmable Gain Instrumentation-Amp
RMS noise: 80 nV (Gain = 64)
Bandgap Reference with 5ppm/ C Drift typ
Power
Supply: 2.7 V to 5.25 V operation
Normal: 400 µA typ
SIGMA DELTA
ADC
IN-AMP
MUX
AIN1(-)
AIN2(+)
SCLK
CS
CONTROL
LOGIC
AIN2(-)
V
GND
DD
INTERNAL
CLOCK
DVDD
IOUT1
IOUT2
AD7792/AD7793
CLK
Power-down: 1 µA max
Update Rate: 4 Hz to 500 Hz
Figure 1.
Simultaneous 50 Hz/60 Hz Rejection
Internal Clock Oscillator
GENERAL DESCRIPTION
Programmable Current Sources (10 µA/200 µA/1 mA)
On-Chip Bias Voltage Generator
100 nA Burnout Currents
Independent Interface Power Supply
16-Lead TSSOP Package
The AD7792/AD7793 is a low power, complete analog front end
for low frequency measurement applications. The
AD7792/AD7793 contains a low noise 16/24-bit ∑-∆ ADC with
three differential analog inputs. The on-chip low noise
instrumentation amplifier means that signals of small
amplitude can be interfaced directly to the ADC. With a gain
setting of 64, the rms noise is 80 nV when the update rate equals
16.6 Hz.
INTERFACE
3-wire serial
SPI®, QSPI™, MICROWIRE™, and DSP compatible
Schmitt trigger on SCLK
The device contains a precision low noise, low drift internal
bandgap reference for absolute measurements. An external
reference can also be used if ratiometric measurements are re-
quired. On-chip programmable excitation current sources can
be used to supply a constant current to RTDs and thermistors
while the 100 nA burnout currents can be used to ensure that
the sensors connected to the ADC are not burnt out. For ther-
mocouple applications, the on-chip bias voltage generator steps
up the common mode voltage from the thermocouple so that it
is within the ADC’s allowable range.
APPLICATIONS
Thermocouple Measurements
RTD Measurements
Thermistor Measurements
FUNCTIONAL BLOCK DIAGRAM
The device can be operated with the internal clock or, alterna-
tively, an external clock can be used if synchronizing several
devices. The output data rate from the part is software pro-
grammable and can be varied from 4 Hz to 500 Hz.
The part operates with a power supply from 2.7 V to 5.25 V. It
consumes a current of 450 uA maximum and is housed in a 16-
lead TSSOP package.
REV.PrF
6/04.
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
Fax: 781.326.8703
www.analog.com
© 2004 Analog Devices, Inc. All rights reserved.