5秒后页面跳转
AD5372_15 PDF预览

AD5372_15

更新时间: 2022-02-26 12:58:04
品牌 Logo 应用领域
亚德诺 - ADI /
页数 文件大小 规格书
29页 722K
描述
32-Channel, 16-/14-Bit, Serial Input, Voltage Output DAC

AD5372_15 数据手册

 浏览型号AD5372_15的Datasheet PDF文件第21页浏览型号AD5372_15的Datasheet PDF文件第22页浏览型号AD5372_15的Datasheet PDF文件第23页浏览型号AD5372_15的Datasheet PDF文件第25页浏览型号AD5372_15的Datasheet PDF文件第26页浏览型号AD5372_15的Datasheet PDF文件第27页 
AD5372/AD5373  
SPECIAL FUNCTION MODE  
If the mode bits are 00, then the special function mode is selected, as shown in Table 15. Bit I21 to Bit I16 of the serial data-word select the  
special function, and the remaining bits are data required for execution of the special function, for example, the channel address for data  
readback. The codes for the special functions are shown in Table 16. Table 17 shows the addresses for data readback.  
Table 15. Special Function Mode  
I23 I22 I21 I20 I19 I18 I17 I16 I15 I14 I13 I12 I11 I10 I9 I8 I7 I6 I5 I4 I3 I2 I1 I0  
0
0
S5  
S4  
S3  
S2  
S1  
S0  
F15 F14 F13 F12 F11 F10 F9 F8 F7 F6 F5 F4 F3 F2 F1 F0  
Table 16. Special Function Codes  
Special Function Code  
Data (F15 to F0)  
Action  
S5 S4 S3 S2 S1 S0  
0
0
0
0
0
0
0
0
0
0
0
1
0000 0000 0000 0000  
XXXX XXXX XXXX X[F2:F0]  
NOP.  
Write control register.  
F4 = overtemperature indicator (read-only bit). This bit should be 0 when  
writing to the control register.  
F3 = reserved. This bit should be 0 when writing to the control register.  
F2 = 1: Select Register X1B for input.  
F2 = 0: Select Register X1A for input.  
F1 = 1: Enable thermal shutdown mode.  
F1 = 0: Disable thermal shutdown mode.  
F0 = 1: Software power-down.  
F0 = 0: Software power-up.  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
1
1
1
1
0
0
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
XX[F13:F0]  
XX[F13:F0]  
Reserved  
See Table 17  
XXXX XXXX [F7:F0]  
XXXX XXXX [F7:F0]  
XXXX XXXX [F7:F0]  
XXXX XXXX [F7:F0]  
Reserved  
Write data in F13 to F0 to OFS0 register.  
Write data in F13 to F0 to OFS1 register.  
Select register for readback.  
Write data in F7 to F0 to A/B Select Register 0.  
Write data in F7 to F0 to A/B Select Register 1.  
Write data in F7 to F0 to A/B Select Register 2.  
Write data in F7 to F0 to A/B Select Register 3.  
XXXX XXXX [F7:F0]  
Block write to A/B select registers.  
F7 to F0 = 0: Write all 0s (all channels use the X2A register).  
F7 to F0 = 1: Write all 1s (all channels use the X2B register).  
Table 17. Address Codes for Data Readback1  
F15  
F14  
F13  
F12  
F11  
F10  
F9  
F8  
F7  
Register Read  
X1A register  
0
0
0
0
0
0
1
1
0
X1B register  
C register  
Bit F12 to Bit F7 select the channel to be read back,  
from Channel 0 = 001000 to Channel 31 = 100111  
0
1
1
M register  
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
1
1
1
0
0
0
0
1
1
0
1
1
0
0
1
1
0
1
0
0
1
0
1
0
Control register  
OFS0 data register  
OFS1 data register  
Reserved  
A/B Select Register 0  
A/B Select Register 1  
A/B Select Register 2  
A/B Select Register 3  
Reserved  
1
0
0
1 Bit F6 to Bit F0 are don’t cares for the data readback function.  
Rev. C | Page 23 of 28  
 
 
 
 

与AD5372_15相关器件

型号 品牌 描述 获取价格 数据表
AD5372BCPZ ADI 32-Channel, 16/14, Serial Input, Voltage-Output DACs

获取价格

AD5372BCPZ-RL7 ADI 32-Channel, 16-Bit, Serial Input, Voltage-Output DAC

获取价格

AD5372BSTZ ADI 32-Channel, 16/14, Serial Input, Voltage-Output DACs

获取价格

AD5373 ADI 32通道、14-Bit、串行输入、电压输出型DAC

获取价格

AD5373_15 ADI 32-Channel, 16-/14-Bit, Serial Input, Voltage Output DAC

获取价格

AD5373BCPZ ADI 32-Channel, 16/14, Serial Input, Voltage-Output DACs

获取价格