ACS110-7SN/SB2
Fig. A: Turn-off operation of the ACS110 switch
with an electro-valve: waveform of the pin OUT
Fig. B: ACS110 switch static characteristic.
current IOUT and Out-COM voltage VOUT
.
IOUT
IH
VOUT
VCL
AC LINE TRANSIENT VOLTAGE RUGGEDNESS
The ACS110 switch is able to sustain safely the AC line transient voltages either by clamping the low en-
ergy spikes or by breaking over under high energy shocks, even with high turn-on current rises.
The test circuit of the figure C is representative of the final ACS application and is also used to stress the
ACS switch according to the IEC 61000-4-5 standard conditions. Thanks to the load, the ACS switch sus-
tains the voltage spikes up to 2 kV above the peak line voltage. It will break over safely even on resistive
load where the turn on current rise is high as shown on figure D. Such non repetitive test can be done 10
times on each AC line voltage polarity.
Fig. C: Overvoltage ruggedness test circuit
for resistive and inductive loads according to
IEC61000-4-5 standards.
Fig. D: Current and Voltage of the ACS110 dur-
ing IEC61000-4-5 standard test with R = 150Ω,
L = 10µH & VPP = 2kV.
R = 150Ω, L = 10µH, VPP = 2kV.
L
R
OUT
ON
ACSxx
S
SURGE VOLTAGE
AC LINE & GENERATOR
VAC + VPP
D
G
COM
RG = 220Ω