AC-DC Converter
AC025 Series
FEATURES:
• Universal Input: 90~264VAC
• High Efficiency Up To 85%
• Protection: Short Circuit/Overload/Overvoltage
• Fully Encapsulated Plastic Case
• Internal Input Filter
• RoHS Compliant
AC-DC Converter
Specifications typical at TA=25°C nominal input voltage and
rated output current unless otherwise specified
AC025 SERIES
Output
Output
Voltage
Output
Current
Ripple &
Noise
Efficiency
(% TYP)
25Watt
3KV Isolated
Wattage
Part Number
(mV) Max
(Note)
(W)
(V)
(mA)
Single & Dual Output
Module
AC025-D05
AC025-D15
AC025-D24
AC025-S03
AC025-S12
AC025-S15
AC025-S16
AC025-S1±
AC025-S24
AC025-S27
AC025-S36
AC025-S4±
25
24
±5
±15
±24
3.3
12
±2500
±±00
±500
5000
2100
1750
1625
1450
1100
1000
750
150
150
150
150
150
200
200
200
240
240
240
240
75
±0
±0
75
±0
±2
±2
±2
±5
±5
±5
±5
24
16.5
25
26
15
26
16
26
1±
26.4
27
24
27
27
36
27
4±
560
Note:
Ripple & noise is measured by using 20 MHz bandwidth, measured with 47uf
paralleled with a high-frequency 0.47uf capacitor across each output by full load.
Temperature Derating Graph
Input Specifications
Parameters
Conditions
Min
Typ
Max
Units
100
Rated Input
Voltage
Vo, Io nom
100~240
Vac
75
60
50
AC in
DC in
90
120
47
264
370
63
Vac
Vdc
Hz
A
Voltage Range
Line Frequency
Inrush Current
Input Fuse
Vo, Io nom
Vi nom, Io nom
Vi:115VAC
Vi:230VAC
50/60
25
0
Natural Convection
12
Io nom
20
A
-20
50
70
VDE/UL/CCC FUSE 2.5A/250V (Slow blow)
Ambient Temperature (ºC)
1
adam-tech.com
info@adam-tech.com