High Precision Programmable Linear Hall Effect Sensor IC
with EEPROM, Analog Output, and Advanced Output Linearization
A1340
ELECTRICAL CHARACTERISTICS: valid through full operating temperature range, TA, and supply voltage, VCC
BYPASS = 10 nF, unless otherwise specified
,
C
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Unit1
General Electrical Characteristics
Supply Voltage
VCC
ICC
4.5
5
–
–
5.5
15
–
V
mA
V
Supply Current
Supply Zener Clamp Voltage
Hall Chopping Frequency4
VZSUPPLY TA = 25°C; ICC = ICC(max) + 3 mA
fC TA = 25°C
19
–
–
128
–
–
kHz
V
VCC(UV_low) TA = 25°C, UVLO falling
VCC(UV_high) TA = 25°C, UVLO rising
3.5
3.7
4.2
4.45
Undervoltage Lockout Threshold2
Output Electrical Characteristics
Output Saturation Voltage
–
V
VSAT(H)
VSAT(L)
ROUT = 10 kΩ to GND, VCC – VOUT,TA = 25°C
ROUT = 10 kΩ to VCC, TA = 25°C
–
–
0.2
0.2
35
0.3
0.3
42
–
V
V
ILIMIT(SNK) VOUT = VCC(max), TA = 25°C
ILIMIT(SRC) VOUT = GND, TA = 25°C
Vnpp
25
–4
–
mA
mA
mVpp
V
Output Current Limit
–1.6
6
Output Noise Peak to Peak3
Output Zener Clamp Voltage
Output Load Resistance4
Output Load Capacitance4,5
–
VZOUT
RLOAD
CLOAD
TA = 25°C
29
10
–
–
–
VOUT to VCC, VOUT to GND
VOUT to GND
BW = 3000 Hz
BW = 1500 Hz
BW = 375 Hz
–
–
kΩ
nF
–
10
0.75
1.4
4.0
–
–
0.6
1.1
3.2
0.5
0.9
3.24
ms
ms
ms
ms
ms
ms
Power-On Time4,6,7
Response Time7,8
tPO
–
–
BW = 3000 Hz
BW = 1500 Hz
BW = 375 Hz
–
tRESP
–
–
–
–
11 G (gauss) = 0.1 mT (millitesla).
2See Protection Features section.
3Capacitor of 10 nF connected between output and ground.
4Determined by design.
5Clarity of a Read Acknowledge message from the device to the controller will be affected by the amount of capacitance and wire inductance on the device output. In such
case, it is recommended to slow down the communication speed, and to lower the receiver threshold for reading digital Manchester signal to 1 V.
6Defined as time from VCC reaching VCC(min) to VOUT reaching 90% of its steady state. See Definitions of Terms section.
7Parameter is verified by lab characterization with a limited amount of samples.
8Defined time from step in gauss of applied magnetic field to VOUT step reaching 90% of its steady state. See Definitions of Terms section.
Allegro MicroSystems, LLC
115 Northeast Cutoff
5
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com