A Dimensions: [mm]
B Recommended hole pattern: [mm]
D1 Electrical Properties:
Properties
Capacitance
Test conditions
Value
0.0680
310
Unit
µF
Tol.
1 V/ 1 kHz ± 0.2 kHz
C
± 10%
Rated voltage
U
V (AC)
R
Isolation Resistance
Dissipation factor
1 min @ 100V (DC)
@ 1 kHz
R
> 30000 MΩ
min.
max.
max.
max.
max.
Iso
DF
< 0.10
< 0.10
< 0.50
270
%
%
Dissipation factor
@ 10 kHz
DF
Dissipation factor
@ 100 kHz
DF
%
Rate of Voltage Rise
Dielectric strength Pin to Pin
Dielectric strength Pin to Case
dV/ dt
V/ µs
V (DC)
V (AC)
C Schematic:
1 minute
1 minute
1333
2000
E General information:
X2-Safety Class Capacitor; MKP - Metallized Polypropylene
Storage Conditions: 35°C, <45% RH
Operating Temperature: -40°C to +105°C
Climate category: 40/ 105/ 56/ B
Maximum Selfheating (rated): 7°C
Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
FIT according to separate documentation
DESCRIPTION
P ±0.5
L ±0.5
15.0
18.0
12.0
6.0
WCAP-FTXX Film Capacitors
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
H ±0.5
W ±0.5
PL ±0.05
Pin Ø ±0.05
d1
Order.- No.
1.2
1.1
1.0
REV
2015-04-16
2014-08-14
2014-05-14
DATE
SSt
SSt
SSt
BY
PSL
PSL
4.0
SIZE
A4
0.8
890334025013CS
Size: Pitch 15.0 mm - PL 4
PSL
1.1
CHECKED
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.