REVISION
THESE DRAWINGS ARE THE PROPERTY OF QUALTEK
ELECTRONICS AND NOT TO BE REPRODUCED FOR
OR COMMUNICATED TO A THIRD PARTY WITHOUT
THE EXPRESS WRITTEN PERMISSION OF AN OFFICER
OF QUALTEK ELECTRONICS.
REV.
B
DESCRIPTION
DATE
APPROVED
DP
RoHS Compliancy
06-01-06
ELECTRICAL CHARACTERISTICS:
1-1.
VOLTAGE RATING...................................115/250VAC
1. PHYSICAL DIMENSIONS
1.55MAX
1-2.
CURRENT RATING
A. @ 115 VAC..........................................10 A RMS MAX
B. @ 250 VAC.........................................10 A RMS MAX
1-3.
1-4.
OPERATING FREQUENCY......................50/60Hz
LEAKAGE CURRENT: EACH LINE TO GROUND
A. @ 115 VAC 60Hz............................0.20 mA MAX
B. @ 250 VAC 50Hz.............................0.40 mA MAX
1-5.
1-6.
HIPOT RATING (FOR ONE MINUTE)
A. LINE TO GROUND...........................2250 VDC
B. LINE TO LINE.....................................1450 VDC
Ø0.13
MINIMUM INSERTION LOSS IN dB: (AT 50 OHM SYSTEM)
1.97MAX
CUTOUT (MOUNTING FROM FRONT)
.10
2
.15
4
.50
10
10
1.0
13
15
5.0
28
25
10
35
30
30
40
40
.01
.05
1
FREQ. MHz
0.02
0
/
/
COM. MODE dB
DIF. MODE dB
1.20
R0.098(2X)
M3
2
4
1
1-7.
1-8.
1-9.
OPERATING TEMPERATURE.................-25° TO +85° C
SAFETY:
R0.04MAX(2X)
RoHS COMPLIANT
1.575 0.005
CONTROLLED
Qualtek Electronics Corp.
2. ELECTRICAL SCHEMATIC
Dim
range
(mm)
Tolerance
PPC DIVISION
858-10/022
+/-
Part Number:
(mm)
L: 0.2mH
C1: 0.1uF
C2: 2200pF
R: 1MΩ
Description:
0-1
1-6
0.15
0.20
0.30
0.50
0.70
0.90
1.20
EMI FILTER
6-18
UNIT: in
REV. B
18-50
50-120
120-250
250-500
Drawn / Date
Approved / Date
JJH / 09-24-01
Checked / Date
09-24-01
B.ZHANG
09-24-01